4.
FAQ
Common problem
Possible cause
Solution
The liquid runs from the pump
back in the stock barrel
Leaking tube, worn rollers,
worn bearings
Replace the tube, replace the rollers, replace
the bearing.
Liquid runs out of the nozzle
while the motor doesn
’
t run
False air between the pump
and the nozzle
Press the hose on the nozzle again, check/
improve the sealing between the coupling and
nozzle again, mount the nozzle 100% vertical.
The motor runs but it doesn
’
t
pump any liquid
The suction tube is closed,
rotor is installed the wrong
way.
Clean the suction tube (possibly by blowing),
install the rotor in the right way.
Leaking feed
-
through coupling
Hose too loose on the cou-
pling
Mount a hose clamp (art. no 001
-
153
-
000) on
the coupling/hose