17
-
30
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
MultiDos
EN
Dosing system –
Dosiersystem –
Systeme de dosage
-
Doseersysteem
Gascoigne Melotte (011
-
038
-
000 motor 24V AC 10RPM Time
-
controlled
GM 3000
1. Enter liquid additive as an extra feedstuff in the GM3000.
2. Enter its name,
“
MultiDos
”
in the processor.
3. Enter dosage at 0,5g/sec.
4. Enter minimum running time at 2sec.
5. Calibration value 60sec.
6. Close
-
off time: not applicable.
Gascoigne Melotte (011
-
038
-
000 motor 24V AC 10RPM Time
-
controlled
ID 2000(+) and )
Key Data,
change the following setting:
06 [enter]: Concentrate ?
Yes
07 [enter]: Scale factor
1
08 [enter]: Min. Dispense
3 gram
10 [enter]: Eating speed
10,9g/sec.
Press the spacebar. The main menu appears again
Type 16 [enter]: Quit, to exit the ID2000 user program. The ID/MR2000 tools
-
menu 1.13
appears.
REMARK: When the Scale factor has been changed all data from all ID2000 Main con-
trollers have to be erased and cow data have to be re
-
entered again.
Feed station Data:
Change the following settings:
09 [enter]: Auger?
Yes
10 [enter]: Feed dispense
10,00g/sec.
11 [enter]: Auger stop time
131 msec.
All other feedtype(s):
01 [enter]: Auger?
Yes
Press the
‘
Arrow Up
’
key to select Feed station 2.
Repeat Chapter 3 for all other Feed stations or type 7[enter]: Entering per batch, to
change the settings for a batch of selected feed stations.
Press the spacebar and type 16[enter]: Quit.
DeLaval ALPRO/DELPRO (Motor 011
-
044
-
000 AC 5 RPM with feedback)
In ALPRO
Menu 2:1 or Menu 2:6
In FP204
Menu 2 (F9)
General
0,05kg = ± 50ml liquid additive.
Calibrition
See
‘
DeLaval ALPRO/feeding system book
’
or
‘
DeLaval ALRPO/program description in-
struction book.
’