10
-
30
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
MultiDos
EN
Dosing system –
Dosiersystem –
Systeme de dosage
-
Doseersysteem
16.
Take the delivery hose, HanskampQualityTube (which is located in the pump) and
1 feed
-
through coupling (art. no. 003
-
572
-
000). Mount this according to diagram
10 and 11.
Attention! When assembling of the hose clamps there is a small chance of
clamp danger.
Attention! Cut the hose off straight. When the hose is cut crooked, may im-
pair the operation.
17.
Turn the rotor of the pump loose by hand (counter
-
clockwise), and remove it
(fig.12)
Attention! By loosening of the rotor by hand, minor injuries can occur.
12
10
11
5