Page EN-29
Installation, fitting, connection
Installation, fitting, connection
Choose a suitable location
CAUTION
Electric shock / fire hazard!
Faulty electrical installation may lead
to electric shocks and/or fire.
■
Do not use a multi-socket extension
cable, multi-socket plug, travel adapt-
er or similar.
■
We recommend using a pulse-sensi-
tive residual current device (RCD).
The planned location must fulfil the following
prerequisites:
– The location must be a dry and frost-safe
room with a firm ground.
– The dishwasher must be positioned be-
neath a full work surface which is joined
together with the cupboards adjacent to
the dishwasher.
– In order to install the connection pipes,
the dishwasher must be positioned near
to a washing/dishwashing basin.
– The measurements of the recess must at
least correspond to the details in the fol-
lowing diagram.
90 °
90 °
600 mm
820mm
100
580mm
80
Inlet/outlet area
and electrical con-
nection.
820 mm
450 mm
90°
90°
580 mm
80 mm
100 mm
Having the outlet hose
connected
NOTICE
Potential malfunction!
Waste water must be able to run away
freely at all times.
■
Ensure that the waste pipe has a di-
ameter of 40 mm.
■
Ensure that there are no kinks or dam-
age to the outlet hose.
■
Make sure that the end of the hose is
not submerged in the pumped water.
■
Do not extend the outlet hose or re-
place with another drainage pipe.
Ø 40 mm
m
ax
. 1000 mm
A
B
The outlet hose (26) can be connected in
two ways:
– Option A:
Connection to a floor drain.
– Option B:
Direct connection to the odour seal
(siphon) of your washing/dishwash-
ing basin. The outlet hose must be a
maximum of 1000 mm above the floor.
Technical measures must be taken for
connection. For this reason, only plumb-
ing experts or employees from our Ser-
vice department may connect the outlet
hose (see page EN-29).