Page EN-14
The hob
The hob has four cooking zones. Each cook-
ing zone corresponds with a dial on the con-
trol panel.
Cooking zone
Ø in cm
Dial
left
rear
16.5
front
20.0
right
front
16.5
rear
20.0
• Turn the dial to the desired level of heat
as needed. See “Tips for saving energy
and for cooking” on page EN-15.
• Turn the dial back to “0” to switch off the
cooking zone.
The indicator lights
When at least one cooking zone is turned on,
the corresponding indicator P lights up.
Residual heat indicators
Cooking zone
Residual heat
indicator
left
rear
front
right
front
rear
The corresponding residual heat indicator
lights up as soon as a cooking zone reach-
es approx. 50 °C. After the cooking zone is
switched off, the indicator continues to be
lit for as long as the cooking zone is hot. It
warns you of any possible burning and lets
you know that you can still use residual heat
to cook.
CAUTION!
Risk of burns!
If a mains failure occurs, the residual
heat indicators will go out and may not
show the presence of residual heat!
■
Do not touch the cooking zones after
a power failure.