Page 26 of 92
520008300 08/14
SmartServe™ Drink Mixers Service Manual
Removal and Replacement
Safety Shield Assembly
The safety shield assembly is located on the front of the machine. The assembly includes a
shield door that can be serviced separately. A magnet embedded in the assembly interacts with
the shield sensor. Some models have two door magnets and sensors. The machine will not
operate if the safety shield assembly is not installed and the door is not closed properly.
WARNING
To avoid risk of serious injury or death, disconnect power to the machine before
cleaning, servicing, or removing parts.
CAUTION
Do not use power tools to remove hardware. Damage to the hardware or the machine
may occur. Do not lose hardware.
To remove the safety shield assembly:
1. Ensure the control panel power switch (1) is in the OFF position and unplug the
machine.
1
2. Remove two thumb screws (2) from the safety shield assembly (3).
3. Slide the safety shield assembly (3) forward to remove from the machine (4).
2
3
4