Page 55 of 92
520008300 08/14
SmartServe™ Drink Mixers Service Manual
Removal and Replacement
Cup-In-Place Sensor (Infrared)
The cup-in-place sensor is located on the front of the machine in the mixing chamber.
To remove the cup-in-place sensor:
1. Remove the safety shield assembly as outlined in this manual.
2. Remove the top cover as outlined in this manual.
3. Remove three screws (1) from each side of the machine.
4. Lift the front panel wrap (2) from the machine.
NOTE:
Avoid overextending the wire harness attached to the interface panel on the wrap.
NOTE:
Cover front panel wrap to avoid scratches/damage from contact with side of machine.
5. Using a large wire tie (3), secure the wrap (2) to the machine using the hole in the top of
the side panel (4).
4
3
2
2
1
6. Raise the cup guard and shield assembly (5) and place a support block (6) under the
shield block (7).
6
5
7