Specifi cations
50 MHz Analog Oscilloscope HM504-2
Valid at 23 °C after a 30 minute warm-up period
Vertical Deflection
Operating Modes:
Channel I or II only
Channels I and II (alternate or chopped)
Sum or Difference of CH I and CH II
Invert:
CH II
XY Mode:
CH I (X) and CH II (Y)
Bandwidth:
2 x 0 - 50 MHz (-3 dB)
Rise Time:
‹ 7 ns
Deflection Coefficient:
1-2-5 Sequence
1 mV/div. – 2 mV/div.:
± 5 % (0 – 10 MHz (-3 dB))
5 mV/div. – 20 V/div.:
± 3 % (0 – 50 MHz (-3 dB))
Variable (uncalibrated):
› 2.5:1 to › 50 V/div.
Input Impedance:
1 MΩ II 15 pF
Input Coupling:
DC, AC, GND (ground)
Max. Input Voltage:
400 V (DC + peak AC)
Triggering
Automatic
(Peak to Peak):
20 Hz – 100 MHz (
≥
5 mm)
Normal with Level Control:
0 – 100 MHz (
≥
5 mm)
Slope:
positive or negative
Sources:
Channel I or II, CH I/CH II alternate (
≥
8 mm),
Line and External
Coupling:
AC (10 Hz – 100 MHz), DC (0 –100 MHz),
HF (50 kHz –100 MHz), LF (0 –1.5 kHz)
Trigger Indicator:
LED
Triggering after Delay:
with Level Control and Slope selection
External Trigger Signal:
≥
0.3 V
pp
(0 – 50 MHz)
Active TV sync. separator:
Field and Line, +/-
Horizontal Deflection
Time Base:
0.5 s/div. – 50 ns/div. (1-2-5 Sequence)
Accuracy:
± 3 %
Variable
(uncalibrated):
› 2.5 :1 to › 1.25 s/div.
X Magnification x 10:
up to 10 ns/div. (± 5 %)
Accuracy:
± 5 %
Delay
(selectable):
140 ms – 200 ns (variable)
Hold-Off Time:
variable to approx. 10 : 1
XY
Bandwidth X amplifier:
0 – 3 MHz (-3 dB)
XY Phase shift ‹ 3°:
‹ 120 kHz
Operation / Readout / Control
Manual:
via controls
Autoset:
automatic signal related parameter settings
Save and Recall:
9 instrument parameter settings
Readout:
display of menu, parameters, cursors and
results
Autom. Measurement:
Freq./Period, Vdc, Vpp, Vp+, Vp-,
Trigger Level
Cursor Measurement:
Δt, 1/Δt, tr, ΔV, V to GND, Gain, Ratio X and Y
Frequency counter:
4 digit (0.01 % ± 1 digit) 0.5 Hz – 100 MHz
Interface
(standard fitting):
RS-232 (for control)
Component Tester
Test Voltage:
approx. 7 V
rms
(open circuit)
Test Current:
max. 7 mA
rms
(short-circuit)
Test Frequency:
approx. 50 Hz
Test Connection:
2 banana jacks 4 mm Ø
One test circuit lead is grounded via protective earth (PE)
Miscellaneous
CRT:
D14-363GY, 8 x 10 cm with internal graticule
Acceleration Voltage:
approx. 2 kV
Trace Rotation:
adjustable on front panel
Z-input
(Intens. modulation): max. + 5 V (TTL)
Calibrator Signal
(Square Wave):0.2 V ± 1 %, 1 Hz – 1 MHz (tr ‹ 4 ns), DC
Power Supply
(Mains):
105 – 253 V, 50/60 Hz ± 10 %, CAT II
Power Consumption:
approx. 34 Watt at 230 V/50 Hz
Ambient temperature:
0° C...+ 40° C
Safety class:
Safety class I (EN61010-1)
Weight:
approx. 5.4 kg
Dimensions (W x H x D):
285 x 125 x 380 mm
Accessories supplied:
Line Cord, Operators Manual and Software for Windows
on CD-ROM, 2 Probes 1:1/10:1 (HZ154)
Optional accessories:
HZ70 Opto Interface (with optical fiber cable)
HM504-2E/140408/ce · Subject to alterations · © HAMEG Instruments GmbH · ® Registered Trademark · DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · info
@
hameg.com
A Rohde & Schwarz Company
w w w . h a m e g . c o m
Summary of Contents for HM504-2
Page 2: ......
Page 3: ...O s c i l l o s c o p e H M 5 0 4 2 Manual English...
Page 39: ...37 Subject to change without notice Front Panel HM504 2...
Page 40: ......
Page 41: ...LEER...