F r o n t   P a n e l   E l e m e n t s   –   B r i e f   D e s c r i p t i o n          

Front Panel Elements – Brief Description

 

POWER

 (pushbutton switch) 

26

    Turns scope on and off.

  

INTENS

 (knob) 

26

 

Intensity for trace- and readout brightness, focus and trace 
rotation control. 

  

  

 

FOCUS, TRACE, MENU

 (pushbutton switch)  

26

 

Calls the Intensity Knob menu to be displayed and enables 
the change of different settings by aid of the INTENS knob. 
See item 2.

 

  

REM

 (pushbutton switch) 

26

 

Switches the displayed menu, the remote mode (REM lit) 
off.  

  

ANALOG/DIGITAL

 (pushbutton switch)  

27

 

Switches between analog (green) and digital mode (blue). 

  

STOP / RUN

 (pushbutton switch) 

27

 

RUN: Signal data acquisition enabled.

 

STOP: Signal data acquisition disabled. The result of the last 
acquisition is displayed. 

  

MATH

 (pushbutton switch) 

27

 

Calls mathematical function menu if digital mode is pre-
sent. 

  

ACQUIRE

 (pushbutton switch) 

28

 

Calls the signal capture and display mode menu in digital 
mode.  

  

SAVE/RECALL

 (pushbutton switch) 

29

 

Offers access to the reference signal (digital mode only) and 
the instrument settings memory.  

 

SETTINGS

 (pushbutton switch) 

30

 

Opens menu for language and miscellaneous function; in 
digital mode also signal display mode. 

 

AUTOSET

 (pushbutton switch) 

30

 

Enables appropriate, signal related, automatic instrument 
settings. 

 

HELP

 (pushbutton switch) 

30

 

Switches help texts regarding controls and menus on and 
off.

 

POSITION 1

 (knob)  

30

 

Controls position of actual present functions: Signal (cur-
rent, reference or mathematics), Cursor and ZOOM (digi-
tal).

 

POSITION 2

 (knob) 

31

 

Controls position of actual present functions: Signal (current, 
reference or mathematics) Cursor and ZOOM (digital).

 

CH 1/2-CURSOR-CH3/4-MA/REF-ZOOM

 (pushbutton)  32

 

Calls the menu and indicates the current function of 

 

POSITION 1 and 2 controls.

 

VOLTS/DIV-SCALE-VAR

 (knob) 

32 

 Channel 1 Y defl ection coeffi cient, Y variabel and Y scaling 
setting.

 

VOLTS/DIV-SCALE-VAR

 (knob) 

32

 

Channel 2 Y defl ection coeffi cient, Y variabel and Y scaling 
setting.

 

AUTO / CURSOR MEASURE

 (pushbutton switch) 

33

 

Calls menus and submenus for automatic and cursor sup-
ported measurement.

 

LEVEL A/B

 (knob) 

34

 

Trigger level control for time base A and B.

 MODE

 (pushbutton switch) 

34

 

Calls selectable trigger modes. 

 

 FILTER

 (pushbutton switch) 

35

 

Calls selectable trigger fi lter (coupling) and trigger slope 
menu. 

 

 SOURCE

 (pushbutton switch) 

35

 

Calls trigger source menu. 

 

 TRIG’d

 (LED) 

36

 

Lit on condition that time base is triggered. 

 

 NORM

 (LED) 

36

 

Lit on condition that NORMAL or SINGLE triggering is pre-
sent.

 

 HOLD OFF

 (LED) 

36

 

Lit if a hold off time 

>

 0% is chosen in time base menu (HOR 

pushbutton 

). 

 

 

X-POS / DELAY

 (pushbutton switch) 

36

 

Calls and indicates the actual function of the HORIZONTAL 
knob 

, (X-POS = dark).

 

 

HORIZONTA

L (knob)  

37

 

Changes the X position resp. in digital mode the delay time 
(Pre- resp. Post-Trigger). 

 

 

 

TIME/DIV-SCALE-VAR 

(knob) 37

 

Time base A and B defl ection coeffi cient, time base variable 
and scaling control.

 

 

MAG 

(pushbutton switch) 

37

 

10 fold expansion in X direction in Yt mode, with simulta-
neous change of the defl ection  coeffi cient display in the 
readout. 

  HOR / VAR

 (pushbutton switch) 

38

 

Calls ZOOM function (digital) and analog time base A and 
B, time base variable and hold off control.  

 

 

CH1 

 (pushbutton switch) 

39

 

Calls channel 1 menu with input coupling, inverting, probe 
and Y variable control.

 

 

VERT/XY

 (pushbutton switch) 

39

 

Calls vertical mode selection, addition, XY mode and band-
width limiter. 

 

 

CH2 

 (pushbutton switch) 

41

 

Calls channel 1 menu with input coupling, inverting, probe 
and Y variable control.

 

 

CH1 

(BNC-socket) 41

 

Channel 1 signal input and input for horizontal defl ection in 
XY mode.

The fi gures indicate the page for complete discriptions 

in the chapter CONTROLS AND READOUT

Summary of Contents for HM1008

Page 1: ...100 MHz CombiScope HM1008 Manual English...

Page 2: ...MC Directive 89 336 EEC amended by 91 263 EWG 92 31 EEC Directive EMC 89 336 CEE amend e par 91 263 EWG 92 31 CEE Niederspannungsrichtlinie 73 23 EWG erg nzt durch 93 68 EWG Low Voltage Equipment Dire...

Page 3: ...Measurement of phase differences in dual channel Yt mode 14 Measurement of amplitude modulation 15 Triggering and time base 15 Automatic peak triggering MODE menu 15 Normal trigger mode See menu MODE...

Page 4: ...me Base 50 s cm 5 ns cm Acquisition modes Single Event Refresh Average Envelope Roll Peak Detect RS 232 Interface optional USB RS 232 IEEE 488 Ethernet USB Signal display Yt and XY Interpolation Sinx...

Page 5: ...e 50 ppm Display 1 MEMORY ZOOM max 50 000 1 Bandwidth X Amplifier 0 100 MHz 3 dB X Y phase shift 3 100 MHz Digital Storage Sampling rate real time 2x 500 MSa s 1 GSa s interleaved Sampling rate random...

Page 6: ...Without pulling the locking knobs they will latch in into the next locking position Handle mounting dismounting The handle can be removed by pulling it out further depending on the instrument model in...

Page 7: ...xplosion The operating position may be any however suf cient ventila tion must be ensured convection cooling Prolonged operation requires the horizontal or inclined position STOP Do not obstruct the v...

Page 8: ...tes the current function of POSITION 1 and 2 controls VOLTS DIV SCALE VAR knob 32 Channel 1 Y de ection coef cient Y variabel and Y scaling setting VOLTS DIV SCALE VAR knob 32 Channel 2 Y de ection co...

Page 9: ...Component Tester Left socket is galvanically connected with protective earth MEMORY oom COMPONENT TESTER PROBE ADJ C O M B I S C O P E POWER 38 39 40 EXIT MENU VOLTS DIV SCALE VAR VOLTS DIV SCALE VAR...

Page 10: ...ich of course must have a suf cient dc rating Care must be taken however when charging and discharging a large capacitor Dc coupling is preferable with all signals of varying duty cyc le otherwise the...

Page 11: ...ead the time difference In the example it was 1 6 cm at 5 ns cm equals 8 ns rise time When measuring very short rise times coming close to the scope rise time it is necessary to subtract the scope s a...

Page 12: ...specially at high sen sitivity one possible reason may be multiple grounding The scope itself and most other equipment are connected to safety ground so ground loops may exist Also most instruments wi...

Page 13: ...herefore please observe the following rule Always look at the two signals in the one channel only or the dual modes and make sure that they are within the permissible input signal range this is the ca...

Page 14: ...ator with trigonometric functions This calculation is independent of the signal amplitudes Please note As the trigonometric functions are periodic limit the calculation to angles 90 degrees This is wh...

Page 15: ...e time base variable or external triggering Reading a and b off the screen the modulation degree will result a b a b m bzw m 100 a b a b a UT 1 m and b UT 1 m When measuring the modulation degree the...

Page 16: ...ve of the polarity of the next slope Rising slope means that a signal comes from a negative po tential and rises towards a positive one This is independent of the vertical position A positive slope ma...

Page 17: ...ed with SOURCE Alt 1 2 The read out will display Tr alt but no more the trigger point symbol indicating level and time position Instead an arrow pointing upwards will indicate the trigger time positio...

Page 18: ...time whereas a DSO can only show a reconstruction of the signal acquired some time later In analog mode thus the display will always start on the left Let us assume one period of a signal is displayed...

Page 19: ...n this mode the Y ampli ers and the time base are turned off Only individual components may be tested i e they must not be part of a circuit if voltages are to be applied to the BNC connectors If the...

Page 20: ...conduct if prior to testing the gate was connected to the source The Rdson will be shown As this can be very low it may look like a plain short although the part is good With enhancement type MOSFETs...

Page 21: ...t the signal is a sine wave It is easily under stood that in order to depict an unknown signal shape one needs at least 1 or 2 points per centimeter in other words the useful signal frequency is only...

Page 22: ...al capture is triggered in SINGLE REFRESH ENVELOPE and AVERAGE modes and untriggered in ROLL and XY modes The normal Refresh mode is similar to the operating mode of an analog scope Triggering will ca...

Page 23: ...lained the maximum sampling rate must be reduced for slow time base settings This may cause aliases If e g a sine wave is sampled only with one sample per period and if it should be synchronous with t...

Page 24: ...eters are N 8 2 no parity 8 bits data 2 stop bits RTS CTS hardware protocol Selection of Baud rate Baud rate setting is automatic Range 110 to 115200 no parity 8 bits data 2 stop bits The rst SPACE CR...

Page 25: ...ess and will hence not cause a menu display STOP Please note If a menu is shown some other information dis played in the readout may disappear this will reappear immediately upon leaving the menu Each...

Page 26: ...displayed by ZOOM digital mode only RO Int Readout intensity Focus Focus for signal and readout Readout On Off Turning the readout off will eliminate interference of the readout with the signal s The...

Page 27: ...s blue The operating mode Yt or XY will not be affected If component test mode was selected possible only in analog mode and the scope is switched to digital the operating mode last used when in DSO m...

Page 28: ...ntre With the 2nd acquisition the display will start at the screen left In most cases this is meaningless but the scope may seem not to react at slow time base settings combined with long Posttrigger...

Page 29: ...without the need for a trigger Hence all controls displays and readouts for the trigger and ZOOM will be disabled The readout will show rol The result of the last acquisition will be displayed at the...

Page 30: ...1 MByte samples may be acquired but only up to 2 KBytes per channel can be displayed hence possibly min or max values may not be shown Otherwise the display is as described above AUTOSET Choosing AUT...

Page 31: ...Mathematics signal position DSO mode only The POSITION 1 control will assume the function of position con trol for mathematics signals after the following procedure Press the MATH pushbutton Display u...

Page 32: ...alibrated The results of cursor measurements will be agged accordingly In this mode the sensitivity can be changed with the VOLTS DIV SCALE VAR control knob from 1 mV cm to 20 V cm 16 3 SCALE DSO mode...

Page 33: ...AUTO CURSOR MEASURE pushbutton Pressing this pushbutton will open the menu Measurement which offers the submenus Cursors and Auto If the submenu Cursors was selected and a measuring mode Cursors On m...

Page 34: ...n mode the level can only be selected between the signal s peak values The movement of the trigger symbol is vertical only The range of this symbol is limited in order to prevent that this symbol will...

Page 35: ...ode of the scope C o n t r o l s a n d R e a d o u t any level can be set If the trigger level is set such that no trig gers are generated the automatic triggering will nevertheless start the time bas...

Page 36: ...nly This display will light up if the hold off time was set to 0 in order to indicate that the longer than minimum hold off time may cause a lower rep rate of the time base and thus a darker display S...

Page 37: ...the readout Z and is calibrated Turning the knob CCW will decrease turning it CW will increase the time base speed This can be selected from 20 ms cm to 5 ns cm in a 1 2 5 sequence The maximum expansi...

Page 38: ...ded to the time base B display Press the CH1 2 CURSOR MA REF ZOOM pushbutton which calls the Pos Scale menu Press the function push button TB B this will cause the POSITION 1 knob to act as the positi...

Page 39: ...between 1 mV cm to 20 V cm VERT XY pushbutton This pushbutton switches the vertical menu on off This menu allows to select the operating modes of the vertical ampli ers C o n t r o l s a n d R e a d o...

Page 40: ...correct if the sensitivities of both channels are identical otherwise the readout will show CH1 CH2 C o n t r o l s a n d R e a d o u t Automatic voltage measurements can not be performed in ADD mode...

Page 41: ...n XY DSO mode both channels may be inverted 32 6 Bandwidth Full 20 MHz This pushbutton will select full or 20 MHz bandwidth Full Full bandwidth will be the one given in the speci cations 20 MHz Provid...

Page 42: ...l s a n d R e a d o u t PROBE ADJ connector A square wave signal of 0 2 Vpp is available for the adjustment of 10 1 probes The frequency can be selected by pressing the pushbutton PROBE ADJ and callin...

Page 43: ...43 Subject to change without notice C o n t r o l s a n d R e a d o u t...

Page 44: ...ruments GmbH Industriestra e 6 A Rohde Schwarz company D 63533 Mainhausen registered trademark Tel 49 0 61 82 800 0 DQS Certi cation DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales...

Reviews: