App7-8
Appendix 7 V-Link
- Expansion code
Set the slot number of the CPU memory of the MITSUBISHI PLC or the CPU number of the
YOKOGAWA PLC.
Example:
MITSUBISHI Slot No. 0:
00H
MITSUBISHI Slot No. 1:
01H
YOKOGAWA CPU No. 1:
00H
YOKOGAWA CPU No. 2:
01H
* If no expansion code or port number is required, enter “00” (= 3030 in the ASCII code).
- Port number
1 : 1, Multi-link ....................................................Not used
Multi-drop............................................................PLC port number
Temperature controller........................................Temperature controller port number
- File No.
Specify the file number set in the [Memory Card Setting] dialog of the V-SFT editor.
- Record No.
Specify the record number set in the [Memory Card Setting] dialog of the V-SFT editor.
- System reserved
Enter “0” (= 30 in the ASCII code) for the number of bytes.
The number of bytes for “system reserved” varies depending on the model.
Example:
Sum Check Code (SUM): 2 bytes
Data is added up (SUM), and the lower one byte (8 bits) of the sum is converted into the 2-digit ASCII
code (hexadecimal).
A sum check code is shown below.
Example:
Transmission mode:
without CR/LF, with sum check
Command: 20
(data
read)
Address:
10 words from $u1000 (03E8H)
When reading, a sum check will be performed as shown below.
Response Code: 2 bytes
[ACK]
This code is received at normal termination.
00H
(3030: ASCII)
[NAK]
This code is received at abnormal termination. (ASCII)
For more information, refer to page App7-9.
Model
Bytes
Code (Hexadecimal)
ASCII
V7 internal memory
10
0000000000H
30303030303030303030
STX
V7 port number
Command
Read words
Memory model
Memory type
Address
System reserved
ETX
SUM
01H
20H
0AH
00H
00H
03E8H
0 0 0 0 0 0 0 0 0 0H
B9H
02H
30H31H
32H30H
30H41H
30H30H
30H30H
30H 33H 45H 38H
30H 30H 30H 30H 30H 30H 30H 30H 30H 30H
03H
42H39H
02H + 30H + 31H + 32H + 30H + 30H + 41H + 30H + 30H + 30H + 30H + 30H + 33H + 45H + 38H
+ 30H + 30H + 30H + 30H + 30H + 30H + 30H + 30H + 30H + 30H + 03H = 4B9H
Summary of Contents for V Series
Page 1: ...V Series...
Page 35: ...2 10 2 Allen Bradley PLC Please use this page freely...
Page 41: ...3 6 3 Automationdirect PLC Please use this page freely...
Page 49: ...6 4 6 FANUC PLC Please use this page freely...
Page 53: ...7 4 7 FATEK AUTOMATION PLC Please use this page freely...
Page 79: ...12 8 12 KEYENCE PLC Please use this page freely...
Page 95: ...14 8 14 LG PLC Please use this page freely...
Page 119: ...16 20 16 MITSUBISHI ELECTRIC PLC Please use this page freely...
Page 135: ...20 4 20 SAIA PLC Please use this page freely...
Page 155: ...24 12 24 Siemens PLC Please use this page freely...
Page 163: ...27 4 27 TOSHIBA PLC Please use this page freely...
Page 169: ...29 4 29 Toyoda Machine Works PLC Please use this page freely...
Page 185: ...33 6 33 Yokogawa Electric PLC Please use this page freely...
Page 215: ...App2 8 Appendix 2 n 1 Connection Multi link 2 Please use this page freely...
Page 221: ...App3 6 Appendix 3 n 1 Connection Multi link Please use this page freely...
Page 225: ...App4 4 Appendix 4 1 n Connection Multi drop Please use this page freely...
Page 317: ...App6 48 Appendix 6 Universal Serial Communications Please use this page freely...