Segmented mandrel T213 – Assembly
Fig. 20
9. Check the run-out at the end-stop surface for the
workpiece end-stop [optimum ≤ 0.005 mm].
10.Tighten the cylindrical screws [D] with the correct
tightening torque, see »Maintenance«.
If necessary, repeat this procedure beginning
at step 7. until the best concentricity and run-
out are reached.
11.Tighten the cylindrical screws [E] with the correct
tightening torque, see »Maintenance«.
12.Loosen and remove the transport eye bolts [A]
from the circumference of the clamping device.
The clamping device is assembled.
40