HYDROK – Maintenance
8.2 Cleaning
4. x
NOTE!
Material damage if cleaned with com-
pressed air!
Cleaning the clamping device with compressed
air can force metal chips into thread and
grooves. This can damage or even destroy the
clamping device.
Never clean the clamping device with com-
pressed air!
Auxiliary material required:
Ester-free, non-polar cleaning agent
Soft, lint-free cloth
CAUTION!
Damage of the seal rings when partial dis-
assembly!
When partly disassembling of the stationary
chuck for cleaning / service, the seal rings will
be damaged!
Keep a new set of seal rings ready for re-
assembling.
Fig. 32
1. Disassembled the clamping device [see chapter
»Disassembling the clamping device«].
CAUTION!
Risk of injury due to spring tension!
While disassembling the stationary chuck for
cleaning / preservation, the clamping device
may cause severe injuries.
The partly disassembly may only be done by
HAINBUCH service personnel.
2. Clean all the components listed below with clean-
ing agent and a cloth; remove all oil and grease
residues:
Taper reception
coupling area
Order h49 7144.907-333
83