hs dock
Use
Order h49 7144.907-333
63
8.4 Suitable fluid
The oil grades to be used are described in ISO 3448 Type
HM 32.
NOTE
Damage to components caused by fluids without
sufficient levels of corrosion inhibitor!
The components made of steel materials must be
protected before the usual oxidation process.
Only ever use fluids with sufficient levels of corro-
sion inhibitor.
NOTE
Damage to materials caused by dirty / unprepared
fluid!
For the product to function properly, ensure that
the fluid is cleaned / processed, and that it con-
tains no particles measuring >10 microns [filtered
with a mesh width of 10 microns].
NOTE
Damage to seals caused by the wrong fluid!
Do not use any fluid that attacks and damages the
installed sealing elements. Those installed seal-
ing elements can be made of NBR, Viton and
PUR materials.
Always use ester-free and non-polar fluids.