hs dock
Removal
Order h49 7144.907-333
73
10.3.3 Removal of the hydraulic port variant of the product from the side of the
product - secured using clamping brackets
1. Move the product into its rear limit stop position.
2. Depressurize the hydraulic unit.
3. Attach any lifting gear that may be required.
4. If necessary, fit the mounting aid onto a vertically sus-
pended spindle.
WARNING
Serious injuries can be caused by escaping media
when seals and damaged / missing!
Replace missing or damaged sealing elements.
Ensure that the sealing elements do not fall out or
get damaged during installation / removal, and
apply a thin coat of grease if necessary.
5. Disconnect the hydraulic ports.
6. Remove the clamping brackets from the product and the
machine table.