hs dock
Installation
48
Order h49 7144.907-333
12. Where required, install the clamping brackets needed on
the product and the machine table.
13. Check face run-out on the test surface of the product
[id
eally ≤ 0.01 mm].
If the face run-out is greater than the maximum permitted
value:
1. Remove the product.
2. Clean the locating face and the mating faces of the ma-
chine table / the baseplate and the product.
3. If there is a burr or slight damage to the locating face of
the product and the machine table / the baseplate, rub it
down gently with an oil stone.
4. Reinstall the product.
5. Repeat the alignment process.
6. Repeat the face run-out test.