44
Item Model
3U52S2SG1FA
Function
-
Cooling
Heating
Rating capacity
W
5200
6500
Cooling Pdesign
W
5200
Heating Pdesign(-10
℃
)
W
4600
Rated power input ( outdoor)
W
1150
1340
Rated current input ( outdoor)
A
5.50
6.30
EER / COP
W/W
4.5
4.8
SEER / SCOP
W/W
8.5
4.2
Minimum capacity
W
1500
1800
Minimum power input
W
550
550
Maximum capacity
W
7000
8100
Maximum power input ( outdoor)
W
3400
3400
Power source
-
1PH, 220-240V~, 50/60Hz
Max.Running current ( outdoor)
A / A
14.2
14.2
Power facor(under rating power input)
-
99%
99%
Starting current
A
4
Fuse size (recommended size)
A
25
Outdoor unit
Compressor
Model / Manufacture
-
SVB172FNPMC/ MELCOM
Oil charge and type
-
600CC/FW68S
Type
-
Twin Rotary (DC inverter)
Number
-
1
Fan
Type × Number
-
Axial × 1
Speed
r/min
High 820
Motor output/input power
W
80/100
Air-flows (H/M/L)
m³/h
about 2000
Heat exchanger
Type / Diameter
mm
TP2M / 7.0
row
-
2
Face area
m²
about 0.52
Dimension
(WxDxH)
External
mm
860/308/730
Package
mm
1005/423/815
Refrigerant control method
-
PMVs
Defrosting method
-
Automatic by reversible cycle
Crankcase heater power
W
NONE
Noise level
Sound power level
dB(A)
65
Sound pressure level
dB(A)
52
Weight
Net / Shipping
kg / kg
53/56
Summary of Contents for AB25S2SC1FA
Page 1: ...SYJS 04 2017 REV A Edition 2017 04 service manual R32...
Page 3: ...1 Part 1 General Information 1 Indoor outdoor unit models 2 2 Feature 3...
Page 23: ...21 5 Installation For AB25S2SC1FA AB35S2SC1FA 1 Installation procedure...
Page 24: ...22 AB25S2SC1FA AB35S2SC1FA AB25S2SC1FA AB35S2SC1FA...
Page 25: ...23...
Page 26: ...24...
Page 27: ...25 AB25S2SC1FA AB35S2SC1FA...
Page 28: ...26...
Page 29: ...27 For AD25S2SC1FA AD35S2SC1FA Installation procedure AD25S2SS1FA AD35S2SS1FA...
Page 30: ...28 AD25S2SS1FA AD35S2SS1FA AD25S2SS1FA AD35S2SS1FA...
Page 31: ...29...
Page 32: ...30 AD25S2SS1FA AD35S2SS1FA...
Page 33: ...31...
Page 38: ...36 21mm AD50S2SM1FA AD71S2SM1FA Unit model The size of drain opening...
Page 39: ...37...
Page 54: ...52 2 Dimension 1U71S2SM1FA 860 633 unit mm...
Page 91: ...89 R32 R32 R32 R32 R32 R32 R32 R32 R32 10 2 Read before installation...
Page 92: ...90 3 R32 R32 R32 R32 R32 R32 R32...
Page 93: ...91 R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A...
Page 96: ...94 10 5 Air tightness test...
Page 97: ...95 R32 R32 10 6 Vacuuming...
Page 123: ...121 PCB 0011800410RA 1U71S2SG1FA Power module 0011800377C 1U71S2SG1FA...