161
14. ECO:
(1) Press ECO button and the display will show
.
(2) ECO is valid under all modes, it is memorized among
switch of all modes.
(3) ECO function power-on or power-OFF is memorized.
15. Turbo/Quiet:
(1) Press button “Turbo”, display icon
on remote LCD
display, display icon
of fan speed; Press
button “Quiet”, display icon
on remote LCD display,
display icon
of fan speed.
(2) Turbo and QUIET functions can not exist at the same time,
the latter will replace the former.
(3) If Turbo function is set, press “SLEEP” button to exit
turbo, which means that setting SLEEP function while
canceling turbo function. At the same time, the icon
disappears and icon is shown; if QUIET function is set
at present, press button “SLEEP” while QUIET function is
still kept.
(4) This function is valid under the mode of COOL or HEAT.
(5) Turbo/QUIET functions are not memorized among switch
of all modes/the state of on or OFF.
16. IFP:
(1) Press “IFP” button, display
, IFP function is set,
and press “IFP” button again to cancel.
(2) Press “Follow/Evade” button, display that expresses
following; press it again, display that expresses evading.
Press it the third time to cancel.
(3) If follow/evade functions are set, air-out angle will change
with position of people, so after setting these functions,
Four-side Embedment icons in all sides, up-and-down
SWING and left-and-right SWING icons will disappear.
(4) If air conditioner is in the state of HEALTH
follow/
evade functions is set, HEALTH
function is
cancelled, Four-side Embedment, up-and-down SWING
and left-and-right SWING icons will disappear.
17. FRESH:
(1) FRESH function is valid under the state of ON or OFF.
When air conditioner is OFF, press “FRESH” button,
display icon
on LCD display to enter Fan mode and
low speed. Press “FRESH” button again, this function is
cancelled.
(2) After FRESH function is set, ON or OFF functions are kept.
(3) After FRESH function is set, mode switch function is kept.
18. 10
°
C Heating Function and
°
C/
°
F function
Press “MENU/°F” button to set 10°C Heating function and
°C/°F function. 10°C Heating Function is valid only under the
mode of HEAT, and it is not memorized under the state of ON
or OFF.
19. HEATER:
(1) When HEAT mode is chosen and
is displayed on LCD
display, pressing “HEATER” button can cancel and set
HEATER function.
(2) Auto mode will not start HEATER function automatically,
but can set or cancel HEATER function.
20. Timer:
(1) TIMER ON
•
Press “TIMER ON” button, character “ON” is
press
“+/-“ button to adjust, then press “CONFIRM” button to
if “CONFIRM” button is not pressed within 10 s, TIMER ON
function is cancelled.
•
If time of TIMER ON is the same as that of clock at present,
character “ON” is always
and can not be
it is
necessary to readjust time.
•
When the time of TIMER ON is end, the setting time and
(2) TIMER OFF
•
Press “TIMER OFF” button, character “OFF” is
press “+/-“ button to adjust, then press “CONFIRM” to
if “CONFIRM” is not pressed within 10 s, TIMER OFF function
is cancelled.
•
If time of TIMER OFF is the same as that of clock at present,
character “OFF” is always
and can not
it is
necessary to readjust time.
•
When the time of TIMER OFF is end, the setting time and
character “OFF” disappear.
(3) TIMER ON/OFF
•
After TIMER ON/OFF is set, remote will automatically judge
sequential order of ON/OFF, arrow indicates that the one
performed
points to the one performed second.
•
After the time of clock performed
is end, corresponding
characters of timer “ON/OFF” disappear.
•
If time of TIMER ON is the same as that of TIMER OFF, and
can not be
corresponding character of the latter of
setting time is always
it is necessary to readjust time
and
again.
•
If time of TIMER ON/OFF is the same as that of clock at
present, and can not be
it is necessary to readjust
time and
again.
(4) After setting timer, display the setting of timer
and then
display time all the time, when timer is active, character “ON/
OFF” is always displayed.
21. /-:
•
Press button “+/-“, time will change in terms of 1 min as unit,
pressing and holding the button will change quickly.
22. Clock:
•
Press “Clock” button, “AM” or “PM” displayed at present are
to enter the state of clock adjustment, adjust clock and
then press “CONFIRM” to
•
It is valid under the state of ON/OFF.
23. LIGHT:
No display on remote controller LCD, which is processed by
indoor unit.
24. RESET:
Perform one power on reset operation when RESET button is
pressed.
25. LOCK:
Press button Lock, display Lock symbol on LCD display,
buttons on remote controller can not be used, press button
Lock again to unlock.
26. CODE:
Function reserved.
27. INQUIRE
Function reserved.
Summary of Contents for AB25S2SC1FA
Page 1: ...SYJS 04 2017 REV A Edition 2017 04 service manual R32...
Page 3: ...1 Part 1 General Information 1 Indoor outdoor unit models 2 2 Feature 3...
Page 23: ...21 5 Installation For AB25S2SC1FA AB35S2SC1FA 1 Installation procedure...
Page 24: ...22 AB25S2SC1FA AB35S2SC1FA AB25S2SC1FA AB35S2SC1FA...
Page 25: ...23...
Page 26: ...24...
Page 27: ...25 AB25S2SC1FA AB35S2SC1FA...
Page 28: ...26...
Page 29: ...27 For AD25S2SC1FA AD35S2SC1FA Installation procedure AD25S2SS1FA AD35S2SS1FA...
Page 30: ...28 AD25S2SS1FA AD35S2SS1FA AD25S2SS1FA AD35S2SS1FA...
Page 31: ...29...
Page 32: ...30 AD25S2SS1FA AD35S2SS1FA...
Page 33: ...31...
Page 38: ...36 21mm AD50S2SM1FA AD71S2SM1FA Unit model The size of drain opening...
Page 39: ...37...
Page 54: ...52 2 Dimension 1U71S2SM1FA 860 633 unit mm...
Page 91: ...89 R32 R32 R32 R32 R32 R32 R32 R32 R32 10 2 Read before installation...
Page 92: ...90 3 R32 R32 R32 R32 R32 R32 R32...
Page 93: ...91 R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A...
Page 96: ...94 10 5 Air tightness test...
Page 97: ...95 R32 R32 10 6 Vacuuming...
Page 123: ...121 PCB 0011800410RA 1U71S2SG1FA Power module 0011800377C 1U71S2SG1FA...