97
For 3U52S2SG1FA 3U68S2SG1FA 4U70S2SH1FA 4U85S2SH1FA
No.
Drawing
Name of parts
Quantity
Note
1
Drainage elbow
1
3U52S2SG1FA 3U68S2SG1FA
2
Drainage elbow
3
4U70S2SH1FA 4U85S2SH1FA
3
Rubber cushion
4
3U52S2SG1FA 4U70S2SH1FA
3U68S2SG1FA 4U85S2SH1FA
4
Clap
1
3U52S2SG1FA 3U68S2SG1FA
3
4U70S2SH1FA 4U85S2SH1FA
5
Adaptor(3/8→1/2)
1
3U52S2SG1FA 4U70S2SH1FA
3U68S2SG1FA 4U85S2SH1FA
6
Adaptor(1/2→3/8)
1
4U70S2SH1FA 4U85S2SH1FA
1. Accessories
2. Procedure for Selecting the Location
Accessories supplied with the outdoor unit:
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be
amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise, will not cause a nuisance to
the neighbors of theuser.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient space for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
Locate the unit so that the noise and the discharged hot air will not annoy the neighbors.
7) Install units, power cords and inter-unit cables at least 3048mm away from television and radio sets. This is to
prevent interference to
images and sounds. (Noises may be heard even if they are more than 3048mm away depending on radio wave
conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air
conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from
moisture.
10) On a flat surface that does not collect rain water.
11) Away from strong wind.
12) Away from direct exposure to rain or snow.
13) Away from sea breeze.
14) Away from inflammable materials.
15) Away from high temperature or open flames.
Summary of Contents for AB25S2SC1FA
Page 1: ...SYJS 04 2017 REV A Edition 2017 04 service manual R32...
Page 3: ...1 Part 1 General Information 1 Indoor outdoor unit models 2 2 Feature 3...
Page 23: ...21 5 Installation For AB25S2SC1FA AB35S2SC1FA 1 Installation procedure...
Page 24: ...22 AB25S2SC1FA AB35S2SC1FA AB25S2SC1FA AB35S2SC1FA...
Page 25: ...23...
Page 26: ...24...
Page 27: ...25 AB25S2SC1FA AB35S2SC1FA...
Page 28: ...26...
Page 29: ...27 For AD25S2SC1FA AD35S2SC1FA Installation procedure AD25S2SS1FA AD35S2SS1FA...
Page 30: ...28 AD25S2SS1FA AD35S2SS1FA AD25S2SS1FA AD35S2SS1FA...
Page 31: ...29...
Page 32: ...30 AD25S2SS1FA AD35S2SS1FA...
Page 33: ...31...
Page 38: ...36 21mm AD50S2SM1FA AD71S2SM1FA Unit model The size of drain opening...
Page 39: ...37...
Page 54: ...52 2 Dimension 1U71S2SM1FA 860 633 unit mm...
Page 91: ...89 R32 R32 R32 R32 R32 R32 R32 R32 R32 10 2 Read before installation...
Page 92: ...90 3 R32 R32 R32 R32 R32 R32 R32...
Page 93: ...91 R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A...
Page 96: ...94 10 5 Air tightness test...
Page 97: ...95 R32 R32 10 6 Vacuuming...
Page 123: ...121 PCB 0011800410RA 1U71S2SG1FA Power module 0011800377C 1U71S2SG1FA...