![Hagie UpFront GST 20 Operator'S Manual Download Page 19](http://html1.mh-extra.com/html/hagie/upfront-gst-20/upfront-gst-20_operators-manual_3208785019.webp)
16
III.
SPECIFICATIONS
SPECIFICATIONS
AUXILIARY HYDRAULIC SYSTEM
Type ........................................................................................ Single closed center pump
Pump type ............................................................................... Load sense
SPRAY SYSTEM
Booms
Type ......................................................................................... Wet, with variable row spacing
Standard .................................................................................. 60/80/90 ft. (5 spray sections)
Controls ................................................................................... Electro-hydraulic: fold/lift/level
Level shock absorber .............................................................. Gas-charged accumulator
Outer boom tip hydraulic breakaway…………………………...Self-actuated, auto-reset hydraulic
Solution Fill Connection
Quick-fill connection (male with adapter for female) ............... 3 in. (7.6 cm) I.D.
Solution Tank
Standard .................................................................................. 2000 gal. (7570
ℓ
) stainless steel w/sight gauge
Agitation ................................................................................... Sparge type with electronic
variable speed control
General Spray System
Pump ....................................................................................... Centrifugal - hydraulically driven with
pulse modulated control valve
Solution valves ........................................................................ Electric ball valves
Pressure gauge ....................................................................... 100 PSI glycerin filled
Console ................................................................................... Raven 4600 (GPS-ready)