49
VI.
TROUBLE SHOOTING
SUGGESTED REMEDY
PROBLEM
POSSIBLE CAUSE
No units will lift
Only one unit will not lift
Faulty “AUTO/MANUAL” switch
Blown fuse
Faulty #1 valve, coil, or loose
coil mounting nut
Loose wire connections
Faulty wire connections
Faulty main wire assembly
In “MANUAL” mode: faulty “UP/
DOWN” switch
Light photo sensor assembly
Faulty valve, coil, or loose coil
mounting unit
Loose wire connections
Lights photo sensor not lined up
with reflector
Faulty row wire assembly
Faulty sensor connector wire
assembly
Replace control box
Find short in wire, repair and
replace fuse
Tighten nut or replace coil
Find loose connections, tighten
Replace or repair
Replace or repair
Replace control box
Replace photo sensor
Tighten nut or replace coil
Find loose connections, tighten
Line up sensor with reflector
Replace or repair
Replace or repair
TASSELTROL
®
/LS SYSTEM – ELECTRICAL CONTINUED
C. TASSELTROL
®
/ LS SYSTEM – ELECTRICAL
NOTE:
Disconnect battery when servicing any part of
electrical system to prevent system damage.