19
Section 3
Installation
3.1 Unpacking
Carefully remove the instrument and its accessories from the box and packing material,
referring to the packing list included to confirm that everything has been delivered. Please
visually inspect the instrument for shipping damage. If anything is missing or damaged, contact
the manufacturer or your dealer immediately.
You may want to retain the box and other packing material in case you later need to ship the
instrument. Please dispose safely and ecologically of the box and packing material (if not stored
for future use).
Please read through this manual thoroughly before carrying out the installation.
3.2 Main components
Factory supplied
Your 6110 Total Package Analyzer is shipped with the following components:
WARNING
This section provides necessary information to install and connect the analyzer. The
installation of the analyzer should be performed in accordance with relevant local regulations,
and only by personnel trained and experienced in the installation of the 6110 analyzer.
Disconnect the power supply of the analyzer before carrying out any work inside the analyzer.
Any work inside the analyzer should be performed exclusively by personnel specialized and
authorized to work on electrical installations. In addition, and in accordance with safety
standards, it must be possible to disconnect the power supply of the analyzer in its immediate
vicinity.
WARNING
Electrical danger and fire hazard. Only use the supplied power cable. Only qualified experts
may perform the tasks detailed in the installation section of this manual, while adhering to all
locally valid safety regulations.
CAUTION
Proper ESD (electrostatic discharge) protocols must be followed to prevent damage to the
product when working with the electronic boards.
CAUTION
The instrument is heavy (55 kg) so extreme care must be taken with handling to avoid
damaging the instrument or inflicting personal injury. It is
highly recommended
to use a
pulley system (or similar) attached to the lifting ring located on the top of the instrument when
unpacking. The instrument should always be moved and stored in a vertical position.
NOTICE
To avoid personal injuryIt is recommended to use a pulley system to rem.
Equipment included
Part No.
Instrument
6110 instrument including all sensors pre-installed
Installation kit
2.5 mm Allen key
Power supply cable
Protection film for screen
Protection for rim detector x4
Seal to package (6 items)
33117
Summary of Contents for ORBISPHERE 6110
Page 1: ...DOC024 52 93009 ORBISPHERE Model 6110 Package Analyzer User Manual 08 2013 Edition 5 ...
Page 2: ......
Page 6: ...4 Table of Contents ...
Page 14: ...12 General Information ...
Page 16: ...14 Specifications 2 2 Instrument dimensions Figure 1 Instrument dimensions ...
Page 28: ...26 Installation ...
Page 34: ...32 User Interface and Startup 4 3 Menu structure overview ...
Page 35: ...33 Section 5 Configuration 5 1 Configuration menu overview ...
Page 46: ...44 Configuration ...
Page 56: ...54 Measurement ...
Page 58: ...56 Analysis ...
Page 70: ...68 Spare Parts and Accessories ...
Page 74: ...72 Material Safety Data Sheets MSDS ...
Page 75: ...73 ...