37
96-5047 rev L June 2005
Example #2
Continuing the previous example, we want to index the platter 90 degrees (Step 1), rotate at five degrees/sec
(F5) in the opposite direction for 10.25 degrees (Step 2), and then return home (Step 3).
9.
Push the [MODE] button. Displays blinking.
10.
Push the [DOWN ARROW] once. You should be on Step 2.
11.
Enter [- 1 0 2 5 0] on the key pad. Use CLR if you make a mistake.
12.
Push the [DISPLAY SCAN] button once.
13.
Enter [5 0 0 0] on the keypad.
14.
Push the [DISPLAY SCAN] button twice. A “G 91” will be displayed.
15.
Push the [DOWN ARROW] once. You should be on Step 3.
16.
Enter [8 8] on the keypad.
17.
Push the [UP ARROW] twice. You should be on Step 1.
18.
Push the [MODE] button. Steady displays.
19.
Push the [CYCLE START] switch three times. The table should index 90 degrees (90
o
),
slow feed in the opposite direction for 10.25 degrees (10.25
o
), and return home.