Type of Stop
Function
Interface
communication
How to restart
Safety Stop =
Emergency Stop
on UserTerminal
N
palm switch is hit
N
running belt & inclination system stop fast
N
machine is cut off from main power of
drive motor and inclination system
N
display, keyboard and interface inactive
interrupted
during cut-off
from main power
N
wait 1 minute
N
turn palm switch to
the right
N
push “ON” button at
main power switch
N
press START key at
UserTerminal
or new command via
interface
Safety Stop =
Emergency Stop
N
mushroom switch is hit
N
running belt & inclination system stop fast
N
machine is cut off from main power of
drive motor and inclination system
N
display, keyboard and interface inactive
interrupted
during cut-off
from
main power
N
wait 1 minute
N
pull mushroom switch
N
push “ON” button at
main power switch
N
press START key at
UserTerminal
or new command via
interface
Quick Stop
models venus / saturn
Emergency stop
button is connected to
the “quick stop port”
of the UserTerminal
N
mushroom switch is hit
N
running belt & inclination system stop
extremely fast
N
drive motor is used to stop the running belt
very fast
N
machine is
NOT
cut off from main power
of drive motor and inclination system
N
display active, shows “PULL STOP”
N
interface active, but no start, speed or
elevation signal executed
N
keyboard inactive
NOT
interrupted
during
Quick Stop
stage
N
pull mushroom switch
N
„pull-stop“ advice
stays for 10 seconds
N
press START key at
UserTerminal
or new command via
interface
Quick Stop
at safety arch
N
subject wears chest belt/harness, safety
rope is pulled > approx. 10 kg
N
running belt & inclination system stop very
fast
N
drive motor is used to stop the running belt
very fast on the oversize machines
venus/saturn
N
machine is
NOT
cut-off from main power
of drive motor and inclination system
N
display active & shows “PULL STOP”
N
interface active, but no start, speed or
elevation signal executed
N
keyboard inactive
NOT
Interrupted
during Quick
Stop and/or
“PULL STOP”
stage
N
release weight from
safety rope
N
(for venus / saturn:
„pull-stop“ advice
stays for 10 seconds)
N
press START key at
UserTerminal or new
command via
interface