PCS-1000 User Manual
82
Syntax
*ESE (0
~
255)
Query Syntax
*ESE?
Parameter /
Return Parameter
<NR1>
0~255: Indicates the bit weight of the
Standard Event Enable Register.
Query Example
*ESE 189
Enables all bits except for bit 1 and 6.
*ESR?
Query
Description
Queries the Standard Event Register.
Bit
Bit weight Description
0
1
Operation Complete
1
2
Not used
2
4
Query Error
3
8
Device Error
4
16
Execution Error
5
32
Command Error
6
64
Not used
7
128
Power On
Query Syntax
*ESR?
Parameter
<NR1>
0~255: Indicates the bit weight of the
Standard Event Register.
Query Example
*ESR?
>32
Indicates a command error was encountered.
*SRE
Set
Query
Description
Returns or sets the contents of the Service Request
Enable Register.
Bit
Bit weight Description
0
1
Not used
1
2
Not used
Summary of Contents for PCS-1000