Command line interface
RE-SYNC ON
instructs the DM24 to resynchronize the real-time clock module to GPS
time when a GPS fix is next obtained.
RE-SYNC OFF
cancels a previous
RE-SYNC ON
instruction, so that attaching a GPS
module will no longer cause the DM24 to resynchronize.
6.10.8 ?LITHIUM
Note:
This command is only available in units with a precision real-time
clock module fitted.
Note:
This command is in the extended dictionary: to use it, first type
ok-1
and finish with
[seal]
.
Syntax:
?LITHIUM
Query the current status of the RTC's internal battery.
6.10.9 RE-BOOT
Syntax:
RE-BOOT
(interactive)
Causes the DM24 to reboot after a delay of 2 s.
RE-BOOT
Confirm with 'y' ?
y
Responding to the confirmation message with anything other than
y
will abort the
reboot.
6.11 Data storage and transmission
6.11.1 SHOW-FLASH
Syntax:
SHOW-FLASH
Reports status information about the Flash memory in the DM24, if fitted. For
example, the output from
SHOW-FLASH
for a new system with 8 × 64Mb chips fitted
would look like this:
512MB Flash File buffer : 16 Blocks Written 0 Unread
524,288 Free
Oldest data [16] Blank
Read point [16] Blank
Latest data [16] Blank
File Replay [16] Blank
For a system in use with 1 × 64Mb chip fitted, it might look like this:
82