Command line interface
Reading Node FFC0 .
LaCie Group SA
1394-IDE Rev B2
LaCie DATA BANK drive LUN 0
Logging on @AgentCSR= 0010:00000
Capacity 39.0GB
Press a key for options else
7 seconds to automatic disk backup
At this point, pressing a key will cause the DM24 to display an options menu and
then pause. If you do not press a key within seven seconds, the disk will be
automatically backed up.
The menu looks like this:
Disk Options :-
(A) save All data
(N) save New data
(S) save Selected time window
(D) Directory – contents
(R) Reset disk – overwrite
(X) eXit
A/N/S/D/R/X ?
During the operation of any of these options, progress reports will occasionally be
displayed on the terminal.
6.13.2 MBTRANSFER
Syntax:
size
MBTRANSFER
If a FireWire disk is plugged in to the DM24 when you are
not
running
DISKMENU
, and
there are enough new data in Flash memory, the DM24 will automatically transfer
the new data to the disk.
The
MBTRANSFER
command sets how much new data there needs to be before the
DM24 will power up the disk and transfer it. If the disk is left attached, the DM24
will then wait until it has collected the same amount of data again before starting
another transfer.
size
is the amount of data to transfer, in megabytes; it must be greater than 10 and
less than the total quantity of Flash memory in the device. Larger values will save
power, because the disk needs to be accessed less often.
If you plug a FireWire disk into the DM24 when there is less than
size
Mb of data
ready, no data will be transferred. If you need to transfer smaller amounts of data,
you should use the
DISKMENU
system.
92
Issue U - December, 2021