User module »DVI-CON-Fiber«
70
· Target and user modules
Connection to the matrix switch
Transmission |Tx:
Insert the LC plug of an optical fibre cable.
Connect the other end of the cable to the
Rx
interface of a compatible
Dynamic Port
provided at the matrix switch.
Transmission|Rx:
Insert the LC plug of an optical fibre cable.
Connect the other end of the cable to the
Tx
interface of the same
Dynamic Ports
pro-
vided at the matrix switch.
Power supply
Main Power:
Connect the power cable with the power pack and a power socket.
Red. Power:
Connect the cable of the optional power pack to establish a redundant
power supply. Connect the power cable with the power pack and a power socket of
another power circuit.
Start-up
Turn on the power button of the
Main Power
power pack.
The devices use components with laser technology which comply with laser
class 1.
They meet the requirements according to
EN 60825-1:2007
and
EN 60825-
2:2004+A1:2007
as well as
U.S. CFR 1040.10
and
1040.11
.
Mind the following instructions when dealing with laser beams:
Avoid eye contact with invisible laser beam
on page 2
Always connect optical connections or cover them with protection caps
on page 2
Only use G&D certified transmission modules
on page 2
NOTE:
Use optical fibres with LC plugs to connect the devices. The cables are avail-
able as accessories.
ADVICE:
You can also connect the target module
directly
to a compatible user mod-
ule.
ADVICE:
During the
System Startup
of the suer module. the current hotkey configu-
ration of the matrix switch is shown.