User module »DVI-CON-MC4«
62
· Target and user modules
Connection to the matrix switch
Transmission 1:
Connect this interface to a
Dynamic Port
(RJ45) of the matrix switch.
Transmission 2:
Connect this interface to another
Dynamic Port
(RJ45) of the matrix
switch.
Transmission 3:
Connect this interface to another
Dynamic Port
(RJ45) of the matrix
switch.
Transmission 4:
Connect this interface to another
Dynamic Port
(RJ45) of the matrix
switch.
Power supply
Main Power:
Connect the supplied power cable.
Insert the cable’s Schuko plug in a power socket.
Red. Power:
Connect the connection cable of a compatible power pack to provide the
user module with a second, redundant power supply.
NOTE:
Use category 5e (or better) twisted pair cables to connect the devices.
ADVICE:
You can also connect the target module
directly
to a compatible target mod-
ule.
NOTE:
Use category 5e (or better) twisted pair cables to connect the devices..
Keyb./Mouse
Generic
Transmission 3
Transmission 1
Micro In
Red. Power
DVI / VGA Out 1
LED out
Speaker
Mouse
Keyb.
Transmission 2
DVI / VGA Out 2
Summary of Contents for DP-CON