Target module »DVI-CPU-Fiber-UC«
Target and user modules ·
29
Connection to the matrix switch
Trans. 1|Tx:
Insert the LC plug of a compatible optical fibre cable.
Connect the other end of the cable to the
Rx
interface of a
Dynamic Port
provided at
the first matrix switch.
Trans. 1|Rx:
Insert the LC plug of a compatible optical fibre cable.
Connect the other end of the cable to the
Tx
interface of the same
Dynamic Port
pro-
vided at the first matrix switch.
Trans. 2|Tx:
Insert the LC plug of a compatible optical fibre cable.
Connect the other end of the cable to the
Rx
interface of a
Dynamic Port
provided at
the second matrix switch.
Trans. 2|Rx:
Insert the LC plug of a compatible optical fibre cable.
Connect the other end of the cable to the
Tx
interface of the same
Dynamic Port
pro-
vided at the second matrix switch.
Power supply
Power In:
Connect the cable of the power pack to this interface. Now connect the
power cable to the power pack and a power socket.
The devices use components with laser technology which comply with laser
class 1.
They meet the requirements according to
EN 60825-1:2007
and
EN 60825-
2:2004+A1:2007
as well as
U.S. CFR 1040.10
and
1040.11
.
Mind the following instructions when dealing with laser beams:
Avoid eye contact with invisible laser beam
on page 2
Always connect optical connections or cover them with protection caps
on page 2
Only use G&D certified transmission modules
on page 2
NOTE:
Use optical fibres with LC plugs to connect the devices. The cables are avail-
able as accessories.
IMPORTANT:
For each matrix switch, connect only one
Trans.
interface of the tar-
get module!
ADVICE:
You can also connect the target module
directly
to a compatible user mod-
ule.