© Guldmann
GB/US
-09/2016 •
#550376_3
123
SERVICE AND
REP
AIR
Switch track GH
Install the cover, make sure that the cables lies at the side
and with out risk of getting caught in moving parts .
Secure the screws with Kemlock AS 43 or similar and
tighten the three screws .
Install the change plate, secure the two screws with Kem-
lock AS 43 or similar and tighten the screws .
Turn the switch track on and test the function .
Electrical switching:
When the hand control is activated the tongue must turn
from side to side
Run-trough with out electrical switching:
The switch track shall turn before the hoist touches the
tongue both when the hoist approaches the switch track
from the curve and the straight rail .
Replacement of activation arm
Important
When installation PCB and cables etc . protection against
static electricity must be used .
Remove the old activation arm .