l
76
Service Schedule
Frequency
Procedure
Notes
Weekly
•
Clean rotor window
•
Clean prisms / reflectors
3 - Yearly
•
Replace silica gel
There are four silica gel bags (part#: 98-0001-4) within the
SceneScan:
•
Two are located inside the Rotor, for access follow the
instructions for “Removal and Replacement of the
Rotor Cover”
•
Two further silica gel bags are located at the rear inside
the base chassis, for access follow the instructions for
“Removal and Replacement of the I/O & Controller
Tray”.
•
Replace slip ring
For replacement follow the instructions for “Slip Ring
Replacement”
5 - Yearly
•
Replace rotor and base drive belts
For replacement follow the instructions for:
•
“Rotor Optics Tilt Drive Belt”
•
“Replacement of the Rotor Drive Belt (Spring
Tensioned)”
or
•
“Replacement of the Rotor Drive Belt (Non Spring
Tensioned)”
All maintenance items should be carried out in accordance with the instructions contained within the relevant product guide. If in doubt contact Guidance Marine.
The storage guidelines and recommendations for position reference sensors manufactured by Guidance Marine are:
•
Temperature -25°C to +50°C
•
Humidity less than 90% RH, non-condensing
Note: Prolonged storage may affect service items and post storage service may be required. If you have any queries please do not hesitate to contact Customer Services or your local
sales representative. Details of which can be found on our website.
Sensor Maintenance Requirements and Recommended Storage Conditions