Tilt Optimisation will start. The angle chosen will depend upon the
current mode:
•
Auto Tilt - The Sensor will sweep through all possible tilt angles
to determine the optimum angle for the scene tracking. The left
pane of the dashboard will show the progress of this operation.
•
Manual Tilt - The Sensor will use the current tilt angle for tracking.
Tracking will start once a tilt angle has been selected by the Sensor in Auto Tilt mode,
otherwise the operator / user selects the tilt angle.
To Stop Tracking
While tracking is in progress, a Stop button is nestled
within the Tracking button. Click on the Stop button to
stop tracking.
Tracking
To Start Tracking
1. Ensure that the Dashboard is In Command (see
Command Mode).
2. Press the Start Tracking button.
3. Press Apply on the Apply/Cancel pop-up.
Note that the Sensor may not find a viable scene for
tracking. This can occur (for example) when in open water.
In this scenario the Sensor will continue Tilt Optimisation
by repeating the sweep process indefinitely until a suitable
/ adequate scene is found. This process can be halted by
Stopping Tracking (see below).