Chapter 2: General Information
Sweep Options
Low Capacity Sweeps
There will be approximately 30 percent capacity reduction in the low capacity sweep compared to the
standard sweep.
Figure 2-2
Low capacity sweep details
Table 2-3
Details for 8 in.
Bin
Diameter
# of Inter-
mediate
Wells
Distance
from Center
of Bin to Wall
(A)
Distance
between
Center Well
Gate and
First Inter-
mediate
Well (B)
Distance
between
Intermediate
Wells (C)
Distance
from Center
of Bin to
Angle Ring
(D)
Distance
between
Center of Bin
to End of
Sweep (E)
15'
1
7' - 5-1/2"
4' - 2-1/4"
-
9' - 11-3/16"
7' - 1/2"
18'
1
8' - 11-7/16"
-
11' - 5-3/16"
8' - 7"
21'
2
10' - 5-5/16"
36"
12' - 11-3/16"
10' - 1/2"
24'
2
11' - 11-1/4"
42"
14' - 5-3/16"
11' - 6-1/2"
27'
2
13' - 5-3/16"
60"
15' - 11-3/16"
13' - 1/2"
30'
2
14' - 11"
60"
17' - 5-3/16"
14' - 7-1/2"
33'
3
16' - 4-15/16"
42"
18' - 11-3/16"
16' - 1-1/2"
36'
3
17' - 10-7/8"
60"
20' - 5-3/16"
17' - 7"
42'
4
20' - 10-11/16"
54"
23' - 5-3/16"
20' - 6-1/2"
48'
4
23' - 10-1/2"
62"
26' - 5-3/16"
23' - 6-1/2"
PNEG-2108
8" and 10" Standard Duty and IW Standard Duty
15