![GSi GrainVue Installation Manual Download Page 33](http://html1.mh-extra.com/html/gsi/grainvue/grainvue_installation-manual_2275059033.webp)
Chapter 5: Installing the Power Supply
2. For unstiffened bins, the Fan Control Module (18) should be mounted in the same position noted for
stiffened bins (2-3 sheets clockwise from the bin door at an accessible height from the ground).
Follow the instructions below to install the Fan Control Module on an unstiffened bin.
a. Shorten the two provided unistrut channels (34) to 2'.
b. Mount the shortened unistrut channels (34) vertically on the bin using sheets screws and
washers as shown in
NOTE:
Make sure to maintain 9-3/4" space between the unistrut channels (34).
c. Use the provided enclosure installation kit to mount the Fan Control Module (18) onto the
installed unistrut channels (34).
Figure 5-6
Installing the Fan Control Module (unstiffened bin)
18
Fan Control Module
34
Vertical unistrut
PNEG-2347
Cable Monitoring System
33