![GSi 40-SERIES Construction Manual Download Page 54](http://html1.mh-extra.com/html/gsi/40-series/40-series_construction-manual_2275090054.webp)
Stiffeners Splice
Use the following information to determine the gauge of the splice needed to connect the stiffeners.
Figure 6-5
Stiffener splice
Call Out
Part Number
Description
Length
Available Gauges
A
CTS–4035XX
Stiffener splice
9.938 in. (25.24
cm)
12, 14
B
CTS-4073XX
Stiffener splice
15.906 in. (40.40
cm)
10
Use the following chart to determine the gauge of the splice, which is determined by the gauge of the stiff-
eners that are being connected. If connecting a heavier gauge to a lighter gauge stiffener, always use the
heavier gauge splice for the 13 to 12, 8 to 6 gauge connections.
For example:
If connecting a 13 gauge stiffener to a 12 gauge stiffener, use the 12 gauge splice. If con-
necting an 8 gauge stiffener to a 6 gauge stiffener, use the 10 gauge splice.
Table 6-3
Splice Usage
Stiffener Gauge
Splice Gauge
10 Gauge
12 Gauge
14 Gauge
18
X
17
X
16
X
15
X
14
X
13
X
12
X
11
X
10
X
9
X
8
X
6
X
5
X
2
X
54
PNEG-4472
72 Ft Diameter Z-Tek Bins
Summary of Contents for 40-SERIES
Page 6: ...NOTES 6 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 18: ...NOTES 18 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 26: ...NOTES 26 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 34: ...NOTES 34 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 72: ...NOTES 72 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 168: ...NOTES 168 PNEG 4472 72 Ft Diameter Z Tek Bins ...