![GSi 40-SERIES Construction Manual Download Page 113](http://html1.mh-extra.com/html/gsi/40-series/40-series_construction-manual_2275090113.webp)
Center Collar Placement
The following figure gives the approximate height needed to install the center collar.
With one sidewall ring in place, position the center collar at the height specified, measuring from the
bottom of the center collar to the foundation as shown. If additional rings are required for construction pur-
poses, add 44 in. for each additional ring.
NOTE:
It is better to set the center collar a little too high. Do not set the center collar too low.
Figure 8-17
Center collar placement
A
251 in. (20 ft - 9 in.) (637.54 cm) from foundation to bottom of center collar on 72 ft diameter bin
NOTE:
Make sure the center pole is adjustable up and down.
PNEG-4472
72 Ft Diameter Z-Tek Bins
113