Figure 8-25
Installing roof panels into exposed gaps
A
Roof panel (CTR-0393)
E
5/16 in. flange nut (S-3611)
B
Exposed gap
F
Upper rib
D
5/16 x 1 in. flange bolt with sealing washer
(S-10260)
G
Lower rib
5. When all roof panels within a group are in place, install the remaining flange bolts and flange nut
along the ribs of each roof panel, and tighten all hardware to the recommended torque specification.
See
Bolt Torque Specifications, page 28
6. Field drill holes (B) into the roof panels (A) through holes in the top of the purlins (D). Fasten the
panels to the roof panel support clips securely using 5/16 in. bolts
NOTE:
Ensure that holes are drilled from inside of the bin.
7. Field drill holes (C) into the roof panels (A) through holes in the top flange of the rafters (E). Fasten
the panels and the rafters securely using 5/16 in. bolts.
NOTE:
Ensure that holes are drilled from inside of the bin.
IMPORTANT:
Failure to properly secure the roof panel to the roof panel support clip and the rafter
will constitute a modification to the product not specifically delineated in this manual
and will void the limited warranty.
122
PNEG-4472
72 Ft Diameter Z-Tek Bins
Summary of Contents for 40-SERIES
Page 6: ...NOTES 6 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 18: ...NOTES 18 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 26: ...NOTES 26 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 34: ...NOTES 34 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 72: ...NOTES 72 PNEG 4472 72 Ft Diameter Z Tek Bins ...
Page 168: ...NOTES 168 PNEG 4472 72 Ft Diameter Z Tek Bins ...