BLOCK MODE:
In Motion Detect Mode, users can set Block Mode to “ON” or “OFF”. When BLOCK MODE is turned on and there
are any variations (e.g. caused by intrusion in the observed area) in the sections of the monitoring image, the
affected parts will be highlighted dynamically.
FRAME SET:
In a monitored field, users can define specific areas as motion detection target zones. Please refer to the
following instructions to configure the parameters for each motion detection zone, the so-called “Frames”. When
motion is detected within a defined frame, the flash warning notice "MOTION" will be displayed in the upper left
corner of the screen.
In total, four frames can be set. Select a frame using the right/left keys on the keyboard, and press “ENTER” key
to enter the frame’s submenu, as shown below.
- LEFT LIMIT:
Move the frame right/left using the right/left keys on the keyboard.
- TOP LIMIT:
Shift the frame up/down using the right/left keys on the keyboard.
- H/V SIZE:
Adjust the frame size via changing the H/V size value using the right/left keys on the keyboard.
- MODE:
Assign a trigger action to a specific motion detection frame. The options include PRESET, SEQUENCE, AUTOPAN
and CRUISE. When motion is detected within a frame, the Dome Camera will execute the specific trigger action.
- DWELL TIME:
The DWELL TIME is duration of executing a trigger action. If select the PRESET mode, when motion is detected,
the Dome Camera will go to the selected Preset position and stay there for a user-defined period of time (1~127
seconds/Always). If you select other modes (SEQUENCE / AUTOPAN / CRUISE), the Dome Camera will keep
executing the selected mode (DWELL TIME: ALWAYS) until alarm condition is released or interrupted by
commands sent from a connected control device.
- EXIT:
Exit the FRAME setting page and go back to the ALARM DETECT main page.
FRAME DISABLE:
Select a frame to be deactivated and press “ENTER”. The selected frame will then be removed from the
monitored field.
THRESHOLD:
The Threshold range is adjustable from 1~255. The smaller the value, the more sensitive it is, i.e. 1: highest
sensitivity, 255: lowest sensitivity.
EXIT:
Exit the ALARM DETECT menu and go back to the MAIN PAGE 3 to set up the WDR function (refer to 5.3.20. WDR
FUNCTION).
30
English