background image

DECT-TELEFON

TELINO

 

BS 

6

100

TELINO

 

BS 

6

105 TAD

TELINO

 

CS 

6

100 

ǵ

DEUTSCH

ENGLISH

FRANÇAIS

ITALIANO

Summary of Contents for CALIOS BS 7100

Page 1: ...DECT TELEFON TELINO BS 6100 TELINO BS 6105 TAD TELINO CS 6100 DEUTSCH ENGLISH FRAN AIS ITALIANO...

Page 2: ...station 8 Connecting CU 6100 accessories 9 The batteries 10 11 OVERVIEW 10 Mobile unit 11 Base station 12 16 BASIC FUNCTIONS 12 Using the telephone 15 Taking a call 15 Ending a call 16 Switching the k...

Page 3: ...t 39 Logging a mobile unit made by another manufacturer on to the base station 39 Logging a mobile unit off of the base station 40 Using several base stations 41 42 OPERATION WITH A TC SYSTEM 41 Diall...

Page 4: ...h or an anti static cloth to clean the base station and the mobile unit Notes on use The telephone is designed to transmit speech signals via telephone networks Any other type of use is not permitted...

Page 5: ...ery strongly influenced by the surroundings Therefore when making very important calls for example during medical emergencies never rely solely on cordless telephones The babyphone function see page 2...

Page 6: ...er with plug Type SNG 065W CON AD 3515 6 5 400 Operating manual Available accessories CU 6100 charging unit for wireless DECT mobile unit Type SNG 065W CON AD 3515 6 5 400 Condition on delivery 6 GETT...

Page 7: ...lish used on furniture the possibility of the device leaving marks cannot be completely excluded if it comes into contact with furniture Grundig will accept no liability for damage of this kind Do not...

Page 8: ...ion until it clicks 2 Plug the mains adapter into the 230 V mains socket The LED on the top of the base station lights up Note To release the Western plug push down the catch and pull out the plug Con...

Page 9: ...ens if the charged batteries are briefly taken out and then put back in New batteries normally only reach their full capacity after they have been charged and discharged several times Although the bat...

Page 10: ...t Scroll up Open the telephone book Scroll down d Make and end connection Select repeat dial R Signal button hook flash required for extension systems M Opens the menu Press briefly to go back one men...

Page 11: ...sible only when using at least two mobile units Call in progress Menu items and settings can be selected Telephone book Base station Paging button Press briefly and all mobile units logged on will rin...

Page 12: ...button 2 Press d to connect The number is dialled 3 Press d to end the connection Using the repeat dial function The repeat dial memory can hold up to 10 external telephone numbers each of up to 30 di...

Page 13: ...the name of the person you want to call in the display or For a targeted search in the telephone book keep pressing the numerical button with the first letter of the name beside it until you see the f...

Page 14: ...ALLS and the first entry 2 Press VIEW to see the entry 3 If there are several entries in the call list display New 3 you can press or to scroll through the entries Note R x indicates how many times th...

Page 15: ...displayed 1 Pick up the mobile unit from the base station The call is automatically accepted To prevent you hanging up by mistake the d button is disabled for 3 seconds or Press d if the mobile unit i...

Page 16: ...g the buttons 1 Press g until the idle display appears again Switching the mobile unit on and off Switching off the mobile unit 1 Press d until Off appears Afterwards the display is blank You cannot u...

Page 17: ...switch the microphone on and off during a call 1 During the call press OPTION 2 Select the Microphone menu item by pressing or 3 Select OFF to switch off the microphone or ON to switch it on Setting t...

Page 18: ...In the first line the menu or the selected function or setting In the second line the possible setting In the third line the operation you can perform with the function buttons indicates that there a...

Page 19: ...the repeat dial list Always enter numbers in the telephone book with the area code otherwise the CLIP name display in the telephone book will not work 1 Press to open the telephone book The first entr...

Page 20: ...st press OPTION and use or to select Copy from telephone book Copy from repeat dial Copy from call list To save the entry press OPTION and then YES 6 To make further entries repeat this procedure star...

Page 21: ...s in the display 3 Press the OPTION function button 4 Select As Emerg No using and then YES to confirm If you have programmed a PIN you will be asked to enter it The emergency number is marked with th...

Page 22: ...s and Alarm menu items and press CONT each time to confirm 3 Select the Snooze menu item by pressing or and press CONT to open it 4 Set the time 5 to 60 minutes using or and press YES to confirm 5 Hol...

Page 23: ...6 Press VOLUME press or to set the volume then YES to confirm 7 Hold down M to finish the setting Switching the ring tone on and off 1 Press M to open the menu 2 Select the Ring tone menu item by pres...

Page 24: ...ect the Direct call menu item by pressing or and select NEW to confirm 3 Press the EDIT function button and enter the direct call number using 1 0 4 Press OPTION and then YES to save the direct call n...

Page 25: ...one is automatically ended after 2 minutes Monitoring then resumes after the preset time call interval Note The babyphone function is only an additional aid to help you monitor your child It is in no...

Page 26: ...rval Specifies the minimum interval immediately 10 2 to 15 minutes between two calls default setting 3 min utes This time also governs the delay between swit ching on the babyphone and it becoming act...

Page 27: ...he Settings and then the Provider menu items and press CONT each time to confirm 3 To set the provider press EDIT and enter the number using 1 0 4 To save the setting press OPTION and then YES 5 Hold...

Page 28: ...ment since the device automa tically switches to the info text when the voice recording memory is full If you have only deactivated the announcement and activated the info text then this is always pla...

Page 29: ...o text is played when the memory for record ing messages is full This is provided you have recorded an info text and activated the function 4 To record the text press EDIT and then NEW 5 Record the te...

Page 30: ...mum recording time can be set between 1 minute and 6 minutes Delete All messages are irrevocably deleted including those which you have not yet played back Remote query This function activates or deac...

Page 31: ...ng to messages New messages are indicated by the flashing symbol in the display and the red LED on the mobile unit flashes if it has been set 1 Press to open the call list The number of new messages i...

Page 32: ...after chapter on page 31 Remote query Note The remote query must have been activated see the Answering machine settings chapter on page 31 You can query and operate the answering machine from an exte...

Page 33: ...OFF or 51 End text status ON OFF For ON you will hear a positive acknowledgement for OFF or no messages you will hear a negative acknowledgement see also page 5 Activating the function 1 Press the bu...

Page 34: ...age and play it back 2 Press the corresponding numerical button followed by 5 to pause playback 3 Press the corresponding numerical button followed by 6 to skip to the next message and play it back Re...

Page 35: ...k first 4 Press to go to the next memo 5 Press PAUSE to interrupt playback and CONT to resume Note To delete the memo press DELETE and then YES Recording calls You can record conversations during call...

Page 36: ...nu items pressing CONT each time to confirm 3 Confirm the Basis A menu item by pressing CONT or If you are using several base stations select the one you require B C D by pressing or and then press CO...

Page 37: ...g an internal call call waiting You can choose to accept the external call or reject it 1 An incoming external call is signalled by a call waiting tone The external telephone number appears in the dis...

Page 38: ...rnal call 2 Press to select an internal call and then press 1 to 5 to select the mobile unit 3 Press 3 CONF to let the internal subscriber join the call Note You can press DISCONN to disconnect the in...

Page 39: ...on the base station for longer than 5 seconds until the LED flashes Logging a mobile unit off of the base station If you want to log a mobile unit off of the base station you have to do this using ano...

Page 40: ...gged in to the base station in quest ion However you can also deliberately assign a mobile unit to a particular base station or have it search for the base station automatically Manual base call 1 Pre...

Page 41: ...The exchange code often 0 required to access the exchange can be stored so that direct access can be selected from a memory repeat dial telephone book call list Since the stored exchange code is also...

Page 42: ...dd a dial pause press EDIT and then OPTION 5 Press OPTION then SAVE then YES to save the exchange code 6 Select the Dial pause P menu item by pressing or and press YES to add the dial pause 7 Hold dow...

Page 43: ...inish the setting Note If the base station is disconnected from the power supply the time and date are reset to 01 JAN 00 00 Setting the menu language You have the choice of German English French Ital...

Page 44: ...Note If you have set melody 1 you will only hear a short signal tone when a call is made 6 Hold down M to finish the setting Setting the ring tone and tune for internal calls 1 Press M to open the men...

Page 45: ...unit for example a flat battery or insufficient reception strength You can switch the signal tones on or off 1 Press M to open the menu 2 Press or to open the Settings and Audio menu items pressing C...

Page 46: ...o finish the setting Setting the display contrast 1 Press M to open the menu 2 Press or to select the Settings Illumination and Contrast menu items pressing CONT each time to confirm 3 Set the contras...

Page 47: ...M to open the menu 2 Press and to open the Settings and Security menu items pressing CONT each time to confirm 3 Enter the new four digit PIN using 1 0 and repeat your entry to confirm 4 Hold down M...

Page 48: ...tem by pressing or and press CONT to confirm 4 Press EDIT and enter the number to block using 1 0 5 Press OPTION and then YES to activate the block 6 Hold down M to finish the setting Note If you have...

Page 49: ...nal state Dial block Settings which have been altered are reset to their original state Base Provider dial mode exchange code dial block number block and number release answering machine TAD end of ca...

Page 50: ...ring calls Up to 8 hours In stand by Up to 4 days Ambient temperature 5 C to 40 C Dimensions Base L x W x H 140mm x 100mm x 61mm Mobile unit L x W x H 135mm x 49mm x 30mm Weight Base 154 g Mobile unit...

Page 51: ...time Delete Date Time Alarm Date time Answ mach TAD Audio Illumination Language Configuration Exchange code Provider Security Dial mode Dial block Direct call Babyphone Reset MENU Alarm 00 00 ON Answ...

Page 52: ...sitivity Activate delay Number of calls Dial interval Call times Selected Telephone book Calls Settings Dial block Base All Number Block no Release no Number Number Pin Alarm Date time Answ mach TAD A...

Page 53: ...A feature of telecommunications systems with at least two mobile units Several internal callers can take part in a call simultaneously Consulting Allows the user to put a call in progress on hold and...

Page 54: ...ension system Calls from one mobile unit to another internal mobile unit are not charged IWV pulse dialling method A dialling method in which the telephone number is transmitted to the exchange by mea...

Page 55: ...tion of the activated answering machine It allows calls to be recorded even while in progress Redial if engaged This is a T Net function which redials a number which was engaged as soon as the call is...

Page 56: ...ber You can suppress transmission of your number for the next call TC system Abbreviation for telecommunications system Telephone number transmission CLIP You see the number of the caller in the displ...

Page 57: ...nnecting 8 Logging off a mobile unit 40 Logging on a mobile unit 37 Multiple 41 Overview 11 Batteries Battery life 9 Charge level 9 Charging 9 Display 9 Disposal 5 Inserting 7 Lifetime 9 Type 53 Batte...

Page 58: ...F Frequency range 53 H Hands free operation 17 Hash button 10 Health 4 I Internal call 38 Internal call Display 11 Internal querying 39 K Key lock Switching off 16 Switching on 16 L LED 11 Listening...

Page 59: ...y 11 Setting 46 Switching off 23 Switching on 23 Room surveillance 27 S Security 5 Security PIN 50 Settings Active after 31 Babyphone number 26 Date 45 End of call 4 Flash time 42 Illumination 48 Reco...

Page 60: ...try 19 Deleting an entry 20 Display 11 Function 19 New entry 19 Telephoning Dialling using the numerical buttons 12 Dialling from the call list 14 Dialling from the telephone book 13 Dialling from the...

Page 61: ...oper use Use of non genuine spare parts or software Criteria regarding properties such as wear and battery life Repair service Send your telephone to us ask the hotline for the address and we will ret...

Page 62: ...Grundig AG Beuthener Str 41 D 90471 N rnberg http www grundig com 72010 770 6000...

Reviews: