41
Grundfos Alldos pumps
Dilution water
* The data booklet is available on www.Grundfosalldos.com.
Main water line
* The data booklet is available on www.Grundfosalldos.com.
Permissible measuring cell type
* The data booklet is available on www.Grundfosalldos.com.
Product number
Electrical data
Pump 1 HCl
For performance data, see the
installation and operating instructions
for the DMI 6.0-8 pump
DMI 6.0-8
Connection on suction side
PE hose 4/6
Connection on discharge side
PTFE 4/6
Pump 2 NaClO
2
For performance data, see the
installation and operating instructions
for the DMI 6.0-8 pump
DMI 6.0-8
Connection on suction side
PE hose 4/6
Connection on discharge side
PTFE 4/6
OCD-162-5-D/G:
Pump 3 ClO
2
For performance data, see the
installation and operating instructions
for the DMI 3.0-10 pump
DMI 3.0-10
OCD-162-10-D/G:
Pump 3 ClO
2
For performance data, see the
installation and operating instructions
for the DMI 6.0-8 pump
DMI 6.0-8
Connection on suction side
PTFE 4/6
Connections on discharge side
PTFE 4/6
OCD-162-5-P/G, -P/H
OCD-162-10-P/G, -P/H
Pump 3 ClO
2
For performance data, see the
installation and operating instructions
for the DDI 209 pump
DDI 5.5-10
Connection on suction side
PTFE hose 4/6
Connections on discharge side
PTFE hose 4/6
Connection for ClO
2
dosing line
PTFE hose 4/6
Protective tube inside diameter
Minimum 9 mm
Stopcock – ball valve
connection
For types, see the
Grundfos Alldos data
booklet*
PE 6/9 mm
Tapping sleeve for dilution water
bleeding
For types, see the
Grundfos Alldos data
booklet*
Hose connection for dilution water at
the solenoid valve
Hose PE 6/9 mm or
pipe PVC 10/12,
pipe G 1/4
Flow meter and cable
(instead of water flow meter)
For types, see
Grundfos Alldos data
booklet*
Tapping sleeve for injection unit
Measures ClO
2
+ pH or redox
AQC-D1
Measures ClO
2
only
AQC-D6
Connection for hose
Sample-water bleeding and drain
See Grundfos Alldos
data booklet*
Grundfos
Grundfos
Alldos
Voltage/
frequency
Equipment
95702474
162-005-10000
230 V,
50/60 Hz
With dosing
pump
DMI 3.0-10
95702475 162-005-10001
115 V,
50/60 Hz
With dosing
pump
DMI 3.0-10
95702476 162-005-10002
230 V,
50/60 Hz
Without
dosing pump
95702477 162-005-10003
115 V,
50/60 Hz
Without
dosing pump
95702478 162-010-10000
230 V,
50/60 Hz
With dosing
pump
DMI 6.0-8
95702479 162-010-10001
115 V,
50/60 Hz
With dosing
pump
DMI 6.0-8
95702480 162-010-10002
230 V,
50/60 Hz
Without
dosing pump
95702481 162-010-10003
115 V,
50/60 Hz
Without
dosing pump
95707848 162-005-10004
230 V,
50/60 Hz
With dosing
pump
DDI 5.5-10
95707849 162-005-10005
115 V,
50/60 Hz
With dosing
pump
DDI 5.5-10
95707850 162-010-10004
230 V,
50/60 Hz
With dosing
pump
DDI 5.5-10
95707851 162-010-10005
115 V,
50/60 Hz
With dosing
pump
DDI 5.5-10
Power supply connection
115 V, 50/60 Hz
or
230 V, 50/60 Hz
Power consumption of the basic
system without external consumer
load
Maximum 100 VA
Power consumption of the whole
system
Maximum 850 VA
Maximum permissible load on the
potential-free output contacts
250 V/2 A
Maximum 550 VA
Electronic protection level
IP65
Enclosure class, dosing pump
IP65
Enclosure class, solenoid valve
IP65