24
Displaying the redox value
1. MAIN MENU > SERVICE > [OK].
2. MEASUREMENT > [OK].
3. REDOX > [OK].
4. Use the [Down] button to select MEASURED VALUE > [OK].
The current redox measured value is displayed:
•
redox measured value: voltage (in mV)
•
set measuring range (in mV).
5. Press [Esc].
Displaying the calibration logbook for redox
1. Use the [Up] button to select CALDATA/LOGBOOK > [OK].
2. REDOX > [OK].
The last 10 calibration data records are listed in chronological
order in the CALDATA/LOGBOOK. Data record 1 is the one that
was last saved.
•
Press [OK] to display the previous data record.
Use the [Up] or [Down] button to scroll more than five lines.
See section
5.13.3 Performing redox calibration
Displaying the temperature of the sample water
1. MAIN MENU > SERVICE > [OK].
2. MEASUREMENT > [OK].
3. TEMPERATURE > [OK].
4. MEASURED VALUE > [OK].
The current measured value is displayed:
•
temperature (in °C)
•
set measuring range.
If the measuring range is exceeded or not reached, a fault has
occurred (for example temperature sensor cable breakage).
5.9.2 Displaying the current dosing flow, controller type,
setpoint and other control parameters
1. MAIN MENU > SERVICE > [OK].
2. ClO
2
CONTROLLER > [OK].
Displaying the current proportional controller data
If the system is controlled with a proportional controller:
MEASUREMENT
ClO
2
REDOX
ORP MEASUREMENT
CALDATA/LOGBOOK
MEASURED VALUE
ORP MEASUREMENT
-1600 mV
-1500 - 1500 mV
MEASUREMENT
ClO
2
REDOX
CALDATA/LOGBOOK
NO.
DATE/TIME
REDOX OFFSET
TEMPERATURE
23 °C
0.0 - 50.0 °C
ClO2 CONTROLLER
Y OUT: 75 %
PROPORT. CONTRL
DOS CAP: 100 %
INTPU: 10 sec.
MIN ON: 1.0 sec.
DOS. FACT.: 1.0
Menu text
Explanation
Y OUT
Controller output signal to the dosing pump,
specifies the dosing flow in % (0-100 %, 100 %
corresponds to 3.0 l/h (OCD-162-5) or 6.0 l/h
(OCD-162-10) with stroke-length adjustment
knob set to 100 %)
PROPORT.
CONTRL
Controller type
DOS CAP
Maximum dosing flow (0-100 %) (the value
entered in the CONTROLLER menu under
DOSING FLOW)
INTPU
Pulse pause time
MIN ON
Minimum operating time
DOS. FACT.
Dosing factor (value calculated by the
Oxiperm Pro)
Summary of Contents for Oxiperm Pro OCD-162-10