OM-CC-E and C/2-E
8
Drain Tank
Drain Tank
drain elbow with a clamp. Do
not
use plastic
pipe. The drain must withstand boiling water.
WARNING
:
DO NOT CONNECT THE DRAIN DIRECTLY TO A
BUILDING DRAIN.
There must be a free air gap between the end of
the hose and the building drain. The free air gap
should be as close as possible to the unit’s drain.
There must also be no other elbows or other
restrictions between the unit drain and the two
inch free air gap.
CAUTION
DO NOT USE PLASTIC PIPE. DRAIN MUST BE
RATED FOR BOILING WATER.
WARNING
BLOCKING THE DRAIN IS HAZARDOUS.
Install the drain line with a constant
downward pitch. This is especially important
for double-stack units. The bottom unit is
conceptually shown below.
IMPORTANT: Do not allow any water traps in the
line. A trap can cause pressure to build up inside
the cavity during steaming, which will make the
door gasket leak.
�
�
�
�
2 in (50mm)
NOTE: Improper drain connection will void the
warranty.
b.
CC10-E and C/2-20E With Drain Tank
CC10-E Models:
A 1½ inch (4 cm) ID hose may be attached to
the supplied drain elbow with a clamp.
C/2-20E Models:
A two inch (51 cm) ID hose may be attached
to the supplied drain elbow with a clamp.
The hose may be connected directly to a
building drain since the drain tank has an air
vent, which eliminates the need for a free air
gap at the building drain. Do not block the air
vent in any way. Do not attach anything to
the vent tube or reduce its size.
Do NOT use plastic pipe in the drain line,
because the drain must withstand boiling
water.
Tabletop Model
Drain Tank
OM-CC-E and C/2-E
8