Groen Convection Combo C/2-E Operator'S Manual Download Page 22

OM-CC-E and C/2-E

22

Troubleshooting Guide

If a problem persists after taking the actions suggested below, call your authorized Groen service representative.

CODE

INDICATES

SUGGESTED ACTION

1

Low water level probe

Try cleaning steam generator to remove contamination from the probes. 

• If either code continues call your Groen Service Agency.

• If both codes are displayed the unit will only operate in the Oven Mode.

• If only one code is displayed the unit will operate in all modes, but water

may overflow from the generator into the cooking chamber during

operations in either the Steam or Combo Modes.

2

High water level probe

3

Maximum generator fill

time (5 minutes) has been

exceeded.

Make sure the water supply is fully turned on and that hoses are not

kinked or pinched.

• If the code is still displayed the unit will operate in the Oven Mode only.

• Call your Groen Service Agency

4

Faulty air probe

• The unit will operate in Steamer and Clean Cycle Modes only.

• Call your Groen Service Agency

6

Faulty generator probe

• The unit will operate in Oven Mode only.

• Call your Groen Service Agency

7

Time Between Fills

Check for a leaky fill valve.

• The unit will operate in Oven Mode only.

• Call your Groen Service Agency

8

Maximum generator drain

time (three minutes) has

been exceeded.

Inspect the drain line and remove any blockage.  Make certain that the

drain is free-vented as detailed in the Installation Section of this Manual. 

(Paragraph 4, Pages 7-8)

Mode Operation —  After a Service Code Occurs

Mode

Service Code

1

2

3

4

6

7

8

1 & 2

Steam

Yes

Yes

No

Yes

No

No

No

No

Combo

Yes

Yes

No

No

No

No

No

No

Oven

Yes

Yes

Yes

No

Yes

Yes

Yes

Yes

Clean

Yes

Yes

No

Yes

No

No

No

No

Door Light:

  The door has a total of four light bulbs, two pair wired in series.  If the top or bottom two bulbs fail to

operate, replace each bulb individually to isolate the failed bulb.  If all bulbs fail to operate, check the installation of

the jumper cord between the door and oven front panel (see Step F and photo on page 19).

OM-CC-E and C/2-E

22

Summary of Contents for Convection Combo C/2-E

Page 1: ...FC CC10 E OPERATOR MANUAL OM CC E and C 2 E Part Number 121085 DOMESTIC MODELS CC10 E 2 CC 0 E C 2 20 E 2 C 2 20E CONVECTION COMBO Combination Steamer Oven THIS MANUAL MUST BE RETAINED FOR FUTURE REFE...

Page 2: ...E OUTSIDE OF THE OVEN DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLOW COOK...

Page 3: ...HOOTING 21 DIAGRAMS AND SCHEMATICS 23 SERVICE LOG 27 References UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook Illinois 60062 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesot...

Page 4: ...s are located on the right side of the front panel Standard controls let you to operate the Convection Combo in any one of three cooking modes 3 As a convection oven 4 As a self contained pressureless...

Page 5: ...bout the minerals in your water The water going to the steam generator should have between 30 and 40 parts per million ppm total dissolved solids TDS and should have a pH acidity rating of 7 0 to 9 0...

Page 6: ...tacked unit from the factory If the unit does not have a factory installed stand the installer must provide a table stand or counter which is strong enough to support the unit Use of casters is not re...

Page 7: ...ction A double stacked unit should have separate protection for the upper and lower steamer ovens CURRENT DEMAND CC10 E MODELS Voltage Current Power 1 Phase 3 Ph per Line 208 44 7 A 27 5 A 9 3 KW 240...

Page 8: ...m unit is conceptually shown below IMPORTANT Do not allow any water traps in the line A trap can cause pressure to build up inside the cavity during steaming which will make the door gasket leak 2 in...

Page 9: ...OM CC E and C 2 E 9 Proper Drain Line Connections 2 in 50 mm OM CC E and C 2 E 9...

Page 10: ...3 4000 1219 4 5000 1524 5 6000 1830 6 7000 2133 7 8000 2438 8 9000 2745 9 10000 3048 10 11000 3353 11 12000 3658 12 13000 3962 13 14000 4267 14 15000 4572 15 5 For C 2 20E only Check Fan Rotation IMPO...

Page 11: ...F Both actions should be completed in about five minutes starting with a cold unit When the set temperature is attained the WAIT light will go off and the READY light will come on NOTE The timer does...

Page 12: ...OM CC E and C 2 E 12 Standard Operating Controls OM CC E and C 2 E 12...

Page 13: ...touch pad once stops the beeper and resets the timer to the time that was last set Pressing twice clears it to 00 00 At the end of a cooking period opening the door is the same as pressing CLEAR once...

Page 14: ...121042 Probe Hold P N 121072 B Operating Instructions 1 Steamer Mode a If the unit is off switch on the electric power by pressing the ON touch pad If the SERVICE light comes on when you turn on the...

Page 15: ...ng the cooking process steaming and the timer will stop but will not reset When you close the door steaming and timing will continue WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM ANY STEAM COMING OUT...

Page 16: ...T lights will turn on The unit can be cooled quickly to the desired cooking temperature by leaving the door open or following the Fast Cool procedure described near the end of this section Paragraph 4...

Page 17: ...the temperature selected the HOT and WAIT lights will turn on The unit can be cooled quickly by leaving the door open or following the Fast Cool procedure described near the end of this section Parag...

Page 18: ...n be cooled quickly by opening the door and pressing START The fan will operate and the Time Status display will show the word COOL This is the only time the fan operates with the door open WARNING DO...

Page 19: ...t spray hot glass with water or chemicals This could cause the glass to break from thermal shock e Use mild soap without abrasives and warm water to clean the door gasket DO NOT use caustic oven clean...

Page 20: ...up degreaser to generator or lightly coat generator area and elements with spray degreaser Put generator cover and right side panel back into position 4 Close door and press START The Time Status disp...

Page 21: ...Loosen the lock nut at the base of the latch pin and turn the latch pin turn clockwise Re tighten the lock nut b After adjustment run the unit to test for further steam leaks c If there is still leaka...

Page 22: ...unit will operate in Steamer and Clean Cycle Modes only Call your Groen Service Agency 6 Faulty generator probe The unit will operate in Oven Mode only Call your Groen Service Agency 7 Time Between F...

Page 23: ...OM CC E and C 2 E 23 CC10 E Heater Schematic CC10 E Control Schematic Diagrams Schematics OM CC E and C 2 E 23...

Page 24: ...OM CC E and C 2 E 24 C 2 20E Control Schematic 208 240 Volts C 2 20E Control Schematic 480 Volts Diagrams Schematics Continued OM CC E and C 2 E 24...

Page 25: ...OM CC E and C 2 E 25 C 2 20E Heater Schematic 208 240 Volts C 2 20E Heater Schematic 480 Volts Diagrams Schematics Continued OM CC E and C 2 E 25...

Page 26: ...OM CC E and C 2 E 26 C 2 20E Heater Schematic 208 240 Volts Units That Meet Canadian Standards Association Requirements Diagrams Schematics Continued OM CC E and C 2 E 26...

Reviews: