![Grifo SEP 40 User Manual Download Page 79](http://html1.mh-extra.com/html/grifo/sep-40/sep-40_user-manual_2264999079.webp)
ITALIAN TECHNOLOGY
grifo
®
Page 69
SEP 40 Rel. 3.10
PROBLEMS RELATED TO SEP 40 TO PC CONNECTION
Due a large variety of parallel port types, a case may occur when the programmer cannot “get
concerted” with the PC. This problem may be shown as none communication between the PC and
the programmer, or by unreliable communication.
- If this behavior occurs, try to connect your programmer to some other PCs or other parallel ports
near you.
- Please remember that the printer port where the programmer is connected must be configured
as IEEE 1284 compatible. You should check in the BIOS configuration of Your computer that
the port is set as ECP/EPP. Or, if You use a multi I/O card, assure that it can be configured and
used as IEEE 1284 compatible.
- Try to set the parallel port as Centronics compatible (or standard, or normal, or SPP, according
to the BIOS manufacturer, all these denominations refer to the same setting for the parallel
port). This could decrease performance but assure the highet communication reliability.
If You can't find any solution, please contact
grifo
®
directly. Provide us an accurate description of
Your PC configuration, including some other circumstances bearing on the problem in question.
Don’t forget please to tell PC type, manufacturer, speed, operating system type and version, resident
programs; your parallel port I/O manufacturer and type.
LEDS
SEP 40 is provided with 4 LEDs to visualize power supply status and operating programmer status.
Please refer to figure 11 to locate the LEDs.
F
IGURE
9: SEP 40 LED
S
DESCRIPTION
TABLE
LED
COLOUR
DESCRIPTION
Power LED
Green
At power on, it lights for a few seconds, then turns
off.
BUSY LED
Red
When on, indicated that the programmer is
accessing the target device for reading or writing.
Do not touch the target device when this LED is
on.
GOOD LED
Green
When on, this LED indicates that the last operation
concluded successfully.
ERROR LED
Yellow
When on, this LED indicated that an error
condition occoured.
Summary of Contents for SEP 40
Page 2: ......
Page 15: ...ITALIAN TECHNOLOGY grifo Pagina 5 SEP 40 Rel 3 10 FIGURA 1 FOTO DEL SEP 40...
Page 19: ...ITALIAN TECHNOLOGY grifo Pagina 9 SEP 40 Rel 3 10 FIGURA 3 CONTENUTO DELLA CONFEZIONE...
Page 64: ...grifo ITALIAN TECHNOLOGY Pagina 54 SEP 40 Rel 3 10...
Page 69: ...ITALIAN TECHNOLOGY grifo Page 59 SEP 40 Rel 3 10 FIGURE 1 PHOTO OF PROGRAMMER SEP 40...
Page 73: ...ITALIAN TECHNOLOGY grifo Page 63 SEP 40 Rel 3 10 FIGURE 3 PACKAGE CONTENT...
Page 118: ...grifo ITALIAN TECHNOLOGY Page 108 SEP 40 Rel 3 10...