DM-300 • DM-310 • DM-330 • DM-350
21
Accuracy (cont’d)
Capacitance—DM-310, DM-330, and DM-350 Only
Range
Accuracy
600.0 nF*
1.9% + 0.2 nF
6.000
µ
F
1.6% + 0.004
µ
F
60.00
µ
F
1.6% + 0.04
µ
F
600.0
µ
F
1.6% + 0.4
µ
F
2000
µ
F
1.6% + 4
µ
F
*Accuracy below 60 nF is not specified.
Notes: Accuracies are for film capacitors (capacitors with negligible
dielectric absorption). Measurements of larger capacitors can take up to
60 seconds. The first reading may be from an incomplete measurement
cycle and should be ignored.
DC Current
Range
Accuracy
Burden Voltage
DM-310, DM-330, and DM-350 Only
6.000 A
0.9% + 0.003 A
6.9 mV/A
10.00 A*
0.9% + 0.03 A
6.9 mV/A
DM-350 Only
600.0
µ
A
1.2% + 0.3
µ
A
1.7 mV/
µ
A
2000
µ
A
1.2% + 3
µ
A
1.7 mV/
µ
A
* 8 A continuous
10 A for 5 minutes max. with 10 minutes cool down interval
AC Current
Accuracy at
Range
50 to 500 Hz
Burden Voltage
DM-310, DM-330, and DM-350 Only
6.000 A
1.2% + 0.003 A
3.3 mV/A
10.00 A*
1.4% + 0.03 A
3.3 mV/A
DM-350 Only
600.0
µ
A
1.2% + 0.3
µ
A
0.15 mV/
µ
A
2000
µ
A
1.2% + 3
µ
A
0.15 mV/
µ
A
* 8 A continuous
10 A for 5 minutes max. with 10 minutes cool down interval
Summary of Contents for DM-300
Page 16: ...16 Continuity Check Typical Measurements DM 310 DM 330 DM 350 DM 300 ...
Page 39: ...DM 300 DM 310 DM 330 DM 350 39 Mesures types Mesure de la tension DM 310 DM 330 DM 350 DM 300 ...
Page 42: ...42 Vérification de la continuité Mesures types DM 310 DM 330 DM 350 DM 300 ...
Page 68: ...68 Controllo della continuità Misure tipiche DM 310 DM 330 DM 350 DM 300 ...
Page 94: ...94 Durchgangsprüfung Typische Messungen DM 310 DM 330 DM 350 DM 300 ...
Page 120: ...120 Verificación de continuidad Mediciones más comunes DM 310 DM 330 DM 350 DM 300 ...
Page 146: ...146 Teste de continuidade Medições mais comuns DM 310 DM 330 DM 350 DM 300 ...
Page 169: ...DM 300 DM 310 DM 330 DM 350 169 Typische metingen Voltagemeting DM 310 DM 330 DM 350 DM 300 ...
Page 171: ...DM 300 DM 310 DM 330 DM 350 171 Weerstandmeting Typische metingen DM 310 DM 330 DM 350 DM 300 ...
Page 172: ...172 Continuïteitscontrole Typische metingen DM 310 DM 330 DM 350 DM 300 ...
Page 183: ...DM 300 DM 310 DM 330 DM 350 183 ...