Pellet burner GP 45 IV 50
Table 7.3. Description of faults/errors, shown on the control module display of a burner from
series “GP IV”.
No
Message shown on
the display
Meaning
Troubleshooting
1.
IGNITION FAILED
-
Check for fuel and auger operation
or ask for servicing assistance;
2.
LOST
FIRE
IN
COMBUSTION
Looses fire during
operation
Check the auger connection, restart the
burner;
3.
STOKER FAULT
Auger connection is
interrupted
Check the auger power supply, possible
reason could be overheating of the
pellets inlet pipe – check the thermo-
stickers;
4.
TEMP- SENSOR LOW Temperature sensor
is switched off1
Check NTC sensor connection
5.
PHOTOSENS
Photo sensor fault
Check the photo sensor condition,
replace it if necessary – to be performed
by servicing assistance;
6.
TEMP
SENSOR
OVERHEAT
High
temperature
read
by
the
temperature sensor
Check the hot water boiler condition, cool
down the appliance;