Pellet burner GP 45 IV 45
7.
FAILURES AND TROUBLESHOOTING.
Table 7.1. Description of the failures during operation of pellet burner from series “GP IV”
and the methods for their removal.
No
Failure
Reason
Troubleshooting
Insufficient heating
output
Increase the burner’s heating output level
Low
assigned
temperature
It is necessary to check the circulations
water temperature assigned in the burner’s
control module;
1.
In case the burner
is mounted to hot
water boiler and
the
room
temperature is low
Low
assigned
temperature of the
room thermostat (if
installed)
It is necessary to check the room thermostat
temperature assignment;
Heating
output
exceeding
the
consumption
Decrease the burner’s heating output level
High
assigned
temperature
It is necessary to check the circulations
water temperature assigned in the burner’s
control module;
2.
In case the burner
is mounted to hot
water boiler and
the
room
temperature is high
High
assigned
temperature of the
room thermostat (if
installed)
It is necessary to check the room thermostat
temperature assignment;
3.
The
burner
is
switched on but
there is not burning
process
No assignment for
operation
Check the operation assignment by the
burner’s control module;
4.
Hard fuel ignition
Low quality pellets It is necessary to change the pellets,
probably their water content is higher than
the required for normal operation of the
appliance;
5.
The fuel ignition is
accompanied
by
abnormal noise
Insufficient
chimney draught
It is necessary to inspect the chimney and
the appliance condition, to which the burner
is mounted and to clean them from the ash
deposits. After cleaning it could be required
to adjust the system’s operation parameters
– ask for servicing assistance;
6.
Overheating of the
appliance to which
the
burner
is
mounted
No heating load or
incorrect
adjustment of the
burner’s
or
the
appliance heating
output
It is necessary to perform inspection of the
correct working order of the system burner-
appliance and its eventual re-adjustment of
the operation parameters – to be performed
by specialist. After cooling of the consuming
appliance and removal of the failure the
emergency thermostat has to be deactivated
(unscrew the protection cover, press the
button and screw the cover back), and after
that start the burner by restarting it;
7.
Fuel
does
not
ignite
No fuel in the
hopper
The fuel hopper that supplies the transport
auger has to be refueled;