weather alert monitoring purposes. A list of event codes can be
found at this web site:
http://www.weather.gov/os/eas_codes.shtml
Each SAME location/event code storage location can be
configured for Entry ON/OFF and Lockout ON/OFF.
When a SAME location/event code storage location is set for
Entry ON, the radio will process the SAME location/event code
that is stored there. When a SAME location/event code storage
location is set for Entry OFF, that SAME location and event code
will be ignored.
When a SAME location/event code storage location is set for
Entry ON
and
Lockout ON, the radio will process the SAME
location/event code that is stored there,
and will lock out the
specified event code.
A SAME location/event code storage
location set for Entry: OFF and Lockout: ON will
not
be
processed, because Entry is set to OFF. In case of a conflict (i.e.,
two identical codes and events are entered, and one is locked
out), the
locked out entry will take precedence.
SAME Entry Examples
Using the Dallas County, TX example above:
SAME Entry 1:
Code: 048113
Event: ***
Entry: ON
Lockout: OFF
SAME Entries 2-10:
Code: ******
Event: ***
Entry: OFF
Lockout: OFF
The above entry for 048113 will receive all SAME messages for
048113.
SAME Entry 1:
Code: 048113
Event: ***
Entry: ON
Lockout: OFF
0715 User Manual
"
Page 57