Veris Drive Operating Instructions
9.
Reset pop-out indicator if necessary.
Refer to Figure 110
It is a good idea to keep a filter element on hand, and
we recommend changing at a minimum on an
annual basis.
•
Between planting seasons, store cab console
inside a relatively stable and dry environment.
•
Avoid direct spray from high pressure washers on
the motor encoder and the external controller box.
These units are sealed from normal moisture, but
high pressure could inject water into the housing.
•
Keep electrical connects free from dirt and grease.
It’s a good idea to occasionally spray the terminals
with contact cleaner to ensure proper connection.
Troubleshooting
If the Drive will not rotate, see Troubleshooting flow
chart and electronics overview.
Check cab console.
No power to cab console - check with voltmeter.
1.
Upper line (set) is visible but no lower line (out
rate and speed) on display: move to
Communication troubleshooting below.
2.
1 or 10 amp fuse on power cable may be blown.
3.
Engage button is not on - check to see if green
indicator light is on.
4.
Use Cab Console Power Tester (P/N 27857) to
check power out of cab console. Install tester
on round 7 pin power/com cable from cab
console. Turn drive on. Green LED shows
power to external controller. Red LED shows
power to solenoid. If LED lights are not lit,
double-check power and connections; replace
cab console if needed.
Check Communication between cab console and
drive
a.
Check to see if power and communication
cable (main harness) is properly connected.
b.
If no lower line on cab console appears (speed
and output rate), and drive will not rotate in
calibration mode, use Cable Continuity Tester
(P/N 27859) to test power and communication
to external controller.
WARNING: TO PREVENT DAMAGE TO COMPONENTS,
DISCONNECT POWER/COM CABLE FROM CAB
CONSOLE AND EXTERNAL CONTROLLER BEFORE
INSTALLING THIS TESTER). Install 4-pin test plug on end
of 4-pin power/com cable before powering the Cable
Continuity Tester - remove before reattaching power/com
cable directly to cab console.
Pop-Out
Indicator
Figure 110
Pop-Out Indicator