Great Plains
| 118-732M | 4/4/19
96
1510P & 1520P
Veris Drive Operating Instructions
•
Check Nominal rates on both the SiteMate
(SiteMate Settings, Step 4), and on the GP
Controller Console (GP Settings, Step 2). These
must be set to the same number.
•
Re-check GP calibration number with metering
wheel and row spacing.
•
The recipe rates from SiteMate are in 4%
increments. If the two rates are within this 4%
range, the units are operating normally.
•
Check the Conversion number (SiteMate
Settings, Step 2). If the recipe requires a target
conversion number, i.e. the recipe is for 25 which
means 25,000 seeds/acre, the target conversion
number will be 1000. In this case the Nominal
rate in SiteMate and the GP Console should be
near 25,000. See SiteMate Setting, Step 4 for
calculating Nominal Rate.
5.
Population Monitor rate does not match GP
Controller Console
•
Make certain that SiteMate and GP Controller
Console agree. If not, see Troubleshooting Step
4 above.
•
Re-check GP calibration number with metering
wheel and row spacing.
•
Re-check planter monitor settings: calibration
number, row spacing, number of rows, swath
width, seed, etc.
•
On small seeds and/or high rates, if population
monitor consistently indicated a lower population
than the GP Controller Console, contact monitor
manufacturer for performance specs for that
application.
6.
GPS signal is not being received by SiteMate
•
Verify that GPS serial port (which is also the
docking port) is not set to PC connection only
(Start/Settings/Communications/PC
Connections).
•
Check GPS settings in Configure/Settings/GPS
settings/COM (typically COM 1, 4800 Baud, 8
data bits, Parity None, and Stop Bits 1).
•
Click Data tab to view GPS details.
Settings for Ag Leader PF3000 Monitors
used with Great Plains Precision Population
Controllers - QUICK REFERENCE GUIDE
(Create a.tgt recipe file in SMS 2.0 or FarmWorks Site
Pro, or other software that will create a.tgt file, and copy it
to an SRAM or Flash card that is compatible with the PF
3000.)
PF3000 Settings:
1.
Press SETUP key. Press SWATH key. Set swath to
that of your Great Plains Precision Seeding System.